Description
The Airway Management Trainer from Ambu is a tabletop intubation head built for teaching airway skills with direct instructor supervision. Its open left side and transparent airway walls let students and instructors watch every tube placement as it happens.
- Training Scope: Endotracheal, nasotracheal and fiberoptic intubation plus supraglottic airway placement
- Airway Visibility: Transparent pharynx and trachea walls show the tube path during practice
- Tooth Protection Feedback: Electronic sensor sounds an acoustic signal when excess pressure hits the upper teeth
- Footprint: 40 x 24 x 35 cm with the transport bag, about 5 kg complete
An Open-Sided Intubation Head That Shows Every Placement
Ambu designed this trainer to teach intubation techniques with all known tubes and supraglottic airway devices. The head reproduces the mouth, nostrils, teeth, tongue, pharynx, larynx, epiglottis, vocal cords, trachea, esophagus and lungs in accurate anatomical detail. Realistic lifting and tilting of the head, together with natural movement of the cervical spine and jaw, mirrors the positioning changes of a real intubation. Instructors can raise or lower the intubation difficulty so the same head can simulate different patient types during a course. Every part can be reached without tools, which keeps cleaning and routine maintenance quick between classes.
Features and Benefits
- Open Left Side: The open side of the head permits active supervision of the student performance during every attempt
- Transparent Airway Walls: The walls of the pharynx and trachea are transparent, enabling the student to follow the tube down the throat
- Acoustic Tooth Signal: Signals triggered by excess pressure on the teeth help the student correct mistakes, and the signal sensitivity can be adjusted
- Adjustable Difficulty: Intubation difficulty can be adjusted so different patient types can be simulated
- Full Technique Range: Placement of orotracheal tubes, laryngeal masks, Combitube, nasotracheal tubes, nasopharyngeal tubes, endotracheal tubes and Guedel airways can all be trained
- Tool-Free Maintenance: All parts can be accessed without the need of tools for cleaning and upkeep
Product Specifications
Product Details
- Brand: Ambu
- Product Type: Airway management training head
- Dimensions: 40 x 24 x 35 cm with the transport bag
- Weight: Approximately 5 kg complete with the transport bag
- Tooth Sensor: Electronic sensor with an acoustic signal for excess pressure on the upper teeth
Training Compatibility
- Endotracheal Tube: 8 mm inner diameter
- Nasotracheal Tube: 7 mm inner diameter
- Laryngeal Mask: Sizes 3 and 4
- Oropharyngeal Airway: 7 mm inner diameter, Ch 30
- Nasopharyngeal Airway: 6 mm inner diameter, Ch 26
- Suction Tube: 4 mm inner diameter, Ch 18
- Stomach Tube: Maximum 9 mm
- Nasogastric Tube: Maximum 7 mm
Sizes and Packaging
- Packaging: SKU 186002000, sold as case of 1
Find more training equipment for skills labs and EMS programs in Educational Supplies at MedicalEx.
Why Choose This Trainer for Airway Skills Programs
Airway skills decay quickly when students cannot see what their hands are doing. This trainer makes each placement visible and gives immediate feedback on tooth pressure, so corrections happen during the attempt instead of after it.
- Visible Technique: Transparent airway walls turn each intubation into a demonstration the whole group can follow
- Immediate Feedback: The acoustic tooth signal flags heavy laryngoscope pressure before it becomes a habit
- One Head, Many Skills: A single unit covers oral and nasal intubation, fiberoptic work, suction and gastric tube practice
- Low Downtime: Tool-free access to every part keeps the trainer in service between sessions
Manuals and Troubleshooting Guides
Frequently Asked Questions
Which tubes and airways can be practiced on this trainer?
The trainer accepts endotracheal tubes of 8 mm inner diameter and nasotracheal tubes of 7 mm inner diameter. It also trains laryngeal masks in sizes 3 and 4, Combitube placement, Guedel airways, suction tubes and stomach tubes.
How does the tooth sensor work?
An electronic sensor in the head triggers an acoustic signal when a student applies too much force to the upper teeth during laryngoscopy. The signal sensitivity can be adjusted, so instructors can set how early the warning sounds.
Can instructors watch the tube during placement?
Yes. The left side of the head is open and the walls of the pharynx and trachea are transparent, so the tube can be followed down the throat during the attempt.
How is the trainer cleaned between classes?
All parts can be accessed without the need of tools, which makes cleaning and maintenance straightforward. Ambu also lists spare parts for this trainer, including the facial skin, the lungs and bronchial tree, and the carrying bag.
How large is the trainer and what does it weigh?
The trainer measures 40 x 24 x 35 cm with its transport bag. It weighs approximately 5 kg complete with the bag, so one instructor can carry and set it up without help.