Arkray

Arkray Multi-Lancet Device 2 Reusable Lancing Device with Seven Depth Settings and Two Head Caps

(No reviews yet) Write a Review
SKU:
660016
Shipping:
Calculated at Checkout
$27.99
Fast Delivery
Fast Delivery
Most ship in 1–2 days
Shipping
$50+ Ship Free
Flat $6.95
30-Day Returns
30-Day Returns
No questions asked
Secure Payment
Secure Payment
100% safe checkout

Description

The Multi-Lancet Device 2 is Arkray’s reusable lancing device, with seven adjustable depth levels and two head caps for fingerstick and alternate site testing. It is warranted for three years and is tested for use with 25G, 26G, 30G, and 33G lancet blades.

  • Seven Depth Levels – the adjustment dial sets lancing depth across a 0 to 3 mm range, starting at level 3 for finger samples.
  • Two Head Caps Included – a white fingerstick cap and a clear AST cap for palm and forearm sampling.
  • Eject Lever – used lancets eject without handling the blade, and the reset lever re-arms the device after an accidental press.
  • Three-Year Warranty – the manufacturer warrants the lancing device for three years.

A Reusable Lancing Device with Real Depth Control

Reusable lancing devices earn their place when one device has to serve one person’s testing routine for years. This device’s dial covers seven depth levels, so the user can start at the manufacturer’s suggested level 3 for fingers and adjust up or down by flow. The alternate site cap supports palm and forearm sampling at the higher depth settings, per the instructions for use. Cleaning is defined in the same document: the device is cleaned and disinfected with Clorox Germicidal Wipes between uses. It is intended for single-person use, and the three-year warranty backs that long service life.

Features and Benefits

Depth System

  • Adjustment Dial – seven levels across a 0 to 3 mm lancing depth range, matched to compatible single-use lancet blades.
  • Tested Lancet Sizes – the device has been tested with 25G, 26G, 30G, and 33G lancets, needle length 2.9 mm to 3.6 mm.

Handling

  • Eject and Reset Levers – the eject lever disposes of the used lancet, and the reset lever restores the trigger after an accidental press.
  • Pinch-Point Head Caps – caps change by pushing while holding the pinch points, matching the cap to the sampling method.

Product Specifications

Device Specifications

  • Device: Reusable lancing device, item 660016.
  • Depth Range: 7 levels, 0 to 3 mm lancing depth.
  • Intended Use: single-person use with sterile, single-use compatible lancet blades. Use only under the direction of a physician or qualified medical personnel.
  • Storage: store between 32 and 122 degrees Fahrenheit in a dust-free location. Use between 50 and 104 degrees Fahrenheit.
  • Cleaning: clean and disinfect with Clorox Germicidal Wipes (EPA Registration 67619-12) per the instructions for use.

Warranty

  • Warranty: three-year manufacturer warranty.

Browse the full Lancets & Lancing Devices range, or shop everything from Arkray.

Why Choose a Dial-Adjustable Lancing Device

Fixed-depth devices force one depth on every finger, every day, regardless of skin or flow. Seven levels let the user settle on the shallowest depth that still produces a reliable sample. The two-cap system then extends the same device to alternate sites without a second purchase.

  • Personalized Depth – seven settings replace the one-depth compromise of basic devices.
  • Two Sites, One Device – fingerstick and alternate site caps are both in the box.
  • Long Service Life – a three-year warranty matches the device’s reusable design.

Manuals and Troubleshooting Guides

Frequently Asked Questions

How many depth settings does the device have?

Seven levels, covering a 0 to 3 mm lancing depth. The instructions suggest starting at level 3 for finger samples and level 7 for palm and forearm samples.

Which lancets work with it?

The device has been tested with 25G, 26G, 30G, and 33G lancet blades, with needle lengths of 2.9 mm to 3.6 mm and total lancet lengths of 25.7 mm to 26.6 mm.

Can the device be shared between people?

No. The instructions for use state the device is for use by a single person only and must not be shared, even within a family.

How is it cleaned?

Clean and disinfect with Clorox Germicidal Wipes (EPA Registration 67619-12), following the procedure in the instructions for use.

What warranty covers the device?

The manufacturer warrants the lancing device for three years.

View AllClose

Warranty Information

Covered by the manufacturer’s three-year warranty.
View AllClose

0 Reviews

View AllClose

Explore our wide range of medical products, enjoy hassle-free shopping, and take advantage of our exclusive offers. Free shipping on orders over $50! Need assistance? Contact our friendly customer support team at (800) 494-5750. Happy shopping!