Description
The Baby Tischler Biopsy Forceps from Marina Medical scale the classic Tischler punch down to a 2 mm x 4 mm jaw for smaller cervical biopsy samples. Two shaft lengths, 8 in and 10 in, let the clinician match reach to the patient and the exam setup.
- 2 mm x 4 mm Jaw – a baby Tischler bite sized for smaller, targeted samples
- Two Shaft Lengths – 8 in and 10 in shafts cover routine and deeper reach exams
- Tischler Punch Action – the familiar up-biting punch mechanism colposcopy teams know
A Smaller Tischler Jaw for Cervical Biopsy Sampling
Cervical biopsy calls for a clean, adequate sample with minimal tissue trauma, and the baby Tischler jaw takes a 2 mm x 4 mm bite suited to targeted lesions and smaller cervices. The punch action cuts and retains the specimen in the jaw, so samples transfer to the specimen container without a second instrument pass.
Choose the 8 in shaft for standard exam reach or the 10 in shaft when the cervix sits deeper or the patient anatomy demands more working length. Both lengths share the same jaw, handle feel and spring action, so switching lengths does not change technique. The forceps are reusable instruments for standard reprocessing between patients.
Features and Benefits
Jaw and Sampling
- Jaw Size: 2 mm x 4 mm baby Tischler punch jaw
- Action: up-biting punch that cuts and retains the specimen
- Application: cervical biopsy sampling during colposcopy and gynecologic exams
Size Options
- Shaft Lengths: 8 in (20 cm) and 10 in (25.5 cm) shafts
- Shared Jaw: both lengths carry the same 2 mm x 4 mm jaw
Product Specifications
Packaging
- Quantity Per Pack: 1 Each
- Packaging by Size: 8 in Shaft: 1 Each, 10 in Shaft: 1 Each
Product Details
- Pattern: Baby Tischler biopsy forceps
Size and Fit
- Jaw Size: 2 mm x 4 mm
- Shaft Lengths: 8 in (20 cm) and 10 in (25.5 cm)
Browse the full Forceps range, or shop everything from Marina Medical.
The Right Bite for Smaller, Targeted Samples
Not every biopsy needs a full size Tischler bite. The baby jaw takes a smaller, cleaner sample from targeted lesions, and the two shaft lengths mean the same instrument covers both routine and deep reach exams.
- 2 mm x 4 mm Jaw – samples targeted lesions without taking excess tissue
- Two Shaft Lengths – one jaw and handle feel across 8 in and 10 in reaches
- Specimen Retaining Punch – the cut sample stays in the jaw for clean transfer
- Colposcopy Standard Pattern – the Tischler mechanism gynecology teams already use
Frequently Asked Questions
What is a baby Tischler forceps used for?
It takes cervical biopsy samples, using a smaller 2 mm x 4 mm punch jaw for targeted lesions and smaller tissue samples.
What shaft lengths are available?
This product offers an 8 in (20 cm) shaft and a 10 in (25.5 cm) shaft, both with the same 2 mm x 4 mm jaw.
How does the baby Tischler differ from a standard Tischler?
The jaw is smaller, 2 mm x 4 mm against the standard 3 mm x 7 mm class jaw, so it takes a smaller bite suited to targeted sampling.
Are the forceps reusable?
Yes. They are reusable instruments and should be cleaned and sterilized between patients following facility protocol.
How many come in a pack?
One forceps per pack, in the shaft length selected.