Description
The Baby Tischler Biopsy Punch scales the classic Tischler bite down for smaller lesions and tighter anatomy, in straight and angled-up stainless steel variants. The smaller bite takes adequate specimens where the full-size Tischler would take more tissue than the site can spare.
- Smaller Baby Bite – reduced bite for small lesions and delicate sites
- Straight and Angled Up – two variants for direct and anterior approaches
- Stainless Steel – reusable construction, fully autoclavable
The Tischler Bite at Baby Scale
Not every lesion justifies a full Tischler bite, and on small or delicate sites the standard bite is overtreatment. The Baby Tischler keeps the tissue-drawing jaw design and shrinks the bite, so the specimen stays adequate while the wound stays small. Medgyn offers the stainless pattern in a straight 8 1/2 inch version and an angled-up 8 1/2 inch version for anterior sites.
Both variants are reusable and fully autoclavable. Colposcopy trays pair them with the full-size Tischler so bite size is chosen per lesion. A titanium version of the Baby Tischler is also available in this catalog.
Features and Benefits
Biopsy Bite
- Reduced Bite Size: smaller bite suits small lesions and delicate tissue
- Tissue-Drawing Profile: jaw design draws tissue in for a clean, complete sample
Variants
- Straight Pattern: direct approach for lesions facing the clinician
- Angled-Up Pattern: upward angle for anterior and canal-facing sites
Product Specifications
Product Details
- Product Type: Cervical biopsy punch forceps, Baby Tischler pattern
- Brand: Medgyn Products
- Material: Stainless steel
- Length: 8 1/2 inches
- Use: Reusable, autoclavable
Packaging and Ordering
- Straight, 8 1/2 in: Each (sold individually)
- Angled Up, 8 1/2 in: Each (sold individually)
- Product Codes (SKUs): 030102, 030140
Browse the full Forceps range, or see every Medgyn Products product we carry.
Adequate Specimens Without Oversized Wounds
Bite size should follow lesion size. The Baby Tischler keeps the proven jaw design and right-sizes the wound for smaller targets.
- Right-sized bites – smaller specimens from smaller lesions
- Two approaches – straight and angled-up in one family
- Reusable value – stainless construction amortizes across hundreds of cycles
Frequently Asked Questions
When is a Baby Tischler used instead of a standard Tischler?
For smaller lesions and delicate sites where the full-size bite would remove more tissue than needed.
What variants are available?
Straight and angled-up, both 8 1/2 inches in stainless steel.
Is it reusable?
Yes, both variants are stainless steel and fully autoclavable.
What bite does it take?
A reduced bite compared with the full-size Tischler’s 7 mm by 3 mm, sized for smaller specimens.
Who makes this punch?
Medgyn Products manufactures this Baby Tischler punch.