Description
BD Cathena Safety IV Catheter is designed for clinicians who need reliable vascular access with enhanced safety and patient comfort. When every insertion counts, this device supports smoother first attempts and reduces the risk of needlestick injury. Ideal for hospital staff and infusion teams seeking a dependable IV catheter with advanced safety features.
- BD Instaflash Needle Technology – Enables improved first-attempt insertion success, helping you feel more confident during procedures.
- Passive Safety Mechanism – Automatically shields the needle after use, reducing exposure risk and supporting peace of mind.
- BD Vialon Catheter Material – Designed to lower the chance of mechanical phlebitis and support longer dwell times for patient comfort.
- High Pressure Rating – Withstands up to 325 psi, allowing for versatile use in power injection and rapid infusions.
- Optimized Flow Rate – Delivers up to 60 mL/min, supporting efficient fluid administration in critical care settings.
Advanced IV Access with Enhanced Safety and Comfort
This peripheral IV catheter combines innovative safety engineering with proven materials to support both clinicians and patients. The notched needle and BD Instaflash Needle Technology are clinically demonstrated to improve first-attempt insertion success, reducing painful hit-and-miss insertions. The passive safety mechanism automatically shields the needle after use, helping protect staff from accidental needlestick injuries. BD Vialon Catheter Material is designed to reduce the chance of mechanical phlebitis by up to 50% and enables longer dwell times for patient comfort. With a high pressure rating of 325 psi and a gravity flow rate of 60 mL/min, this device is well suited for demanding hospital environments. Infusion teams and acute care providers benefit from a catheter that balances safety, performance, and comfort for daily vascular access needs.
Features and Benefits
Insertion Success and Safety
- BD Instaflash Needle Technology – Improves visualization of blood return for more accurate placement and fewer failed attempts.
- Passive Safety Engineered Feature – Shields the needle automatically after use, reducing risk of accidental needlestick injuries.
Material and Patient Comfort
- BD Vialon Catheter Material – Reduces the chance of mechanical phlebitis by up to 50% and supports longer dwell times.
- Notched Needle Design – Facilitates smoother insertion and helps minimize patient discomfort.
Performance and Versatility
- High Pressure Rating – Rated up to 325 psi for use with power injectors and rapid infusions.
- Optimized Gravity Flow Rate – Delivers up to 60 mL/min (3,600 mL/hr) for efficient fluid administration.
- Multiple Flow Rate Options – Supports maximum injector flow rates of 11.0 mL/sec (viscosity ≤ 11.8 cP) and 7.0 mL/sec (viscosity ≤ 27.5 cP).
Product Specifications
Dimensions and Sizing
- Catheter Gauge Size: 20 G
- Catheter Length: 1.25 in (3.18 cm)
- Catheter Inner Diameter: 0.83 mm
- Catheter Outer Diameter: 1.10 mm
Material and Color
- Catheter Material: BD Vialon
- Hub Color: Pink
Performance and Flow
- Gravity Flow Rate: 60 mL/min (3,600 mL/hr)
- High Pressure Rating: 325 psi
- Max Injector Flow Rate (≤11.8 cP): 11.0 mL/sec
- Max Injector Flow Rate (≤27.5 cP): 7.0 mL/sec
Packaging and Sterilization
- Quantity Per Box: 50
- Quantity Per Case: 200
- Safety Engineered Feature: Passive
- Sterilization Method: EtO
Explore More: See all Peripheral IV Catheters | Shop more BD Cathena Products
Engineered for Reliable Vascular Access and Clinician Safety
Choose this advanced IV catheter for a balance of safety, comfort, and performance. The passive safety mechanism and BD Vialon material set it apart from standard options, supporting both staff and patient needs. Its high pressure rating and optimized flow rates make it a versatile choice for a range of clinical applications. Rely on a device that helps you deliver care with confidence and efficiency.
- Automatic Needle Shielding – Reduces risk of accidental needlestick injuries for greater staff safety.
- Longer Dwell Times – BD Vialon material supports extended use and patient comfort.
- High Pressure Compatibility – Rated for 325 psi, suitable for power injection and rapid infusions.
- Efficient Fluid Delivery – 60 mL/min gravity flow rate supports quick administration in urgent care.
- Differentiator: Advanced Safety and Material Technology – Combines passive safety engineering and BD Vialon material for a measurable edge over typical IV catheters.
Frequently Asked Questions (FAQs)
What gauge and length is this IV catheter?
This model is a 20 gauge catheter with a length of 1.25 inches (3.18 cm).
What safety features are included?
The device uses a passive safety mechanism that automatically shields the needle after use to help reduce needlestick risk.
What is the maximum pressure rating?
This catheter is rated for up to 325 psi, making it suitable for power injection and rapid infusions.
What material is the catheter made from?
The catheter uses BD Vialon material, designed to reduce the chance of mechanical phlebitis and support longer dwell times.
What is the gravity flow rate?
The gravity flow rate is 60 mL/min (3,600 mL/hr), supporting efficient fluid administration.
How many catheters are in a box and a case?
Each box contains 50 catheters, and each case contains 200 catheters.
What color is the hub?
The hub is pink for easy gauge identification.
Warranty Information
Additional Information
Length: |
1.25 in (3.18 cm) |
Quantity Per Box: |
50 |
Gauge: |
20 G |
Sterilization Method: |
EtO |
Case Quantity: |
200 |