Description
The BD Low-Sorbing Secondary Set is a non-vented secondary administration set in low-sorbing tubing, with a needle-free valve bag access port. It serves infusion services giving medications whose dose accuracy suffers when standard tubing absorbs the drug.
- Low-Sorbing Tubing – the line material is chosen to reduce drug absorption along the fluid path
- Needle-Free Valve Access – the bag access port takes the secondary container without a needle
- Compact 8 mL Path – the short fluid path primes with very little solution
Secondary Infusions Where the Tubing Keeps Its Hands Off the Drug
Some medications lose potency to the tubing itself, sorbed into standard plastic before they ever reach the patient. Low-sorbing tubing answers that loss directly, and it is the reason this secondary set exists beside standard versions. The rest of the configuration stays practical: needle-free valve access at the bag, roller and pinch clamps for control, and a fixed male luer lock with hanger at the patient end. Its fluid path holds just 8 mL across the 31 inch line, the smallest prime on this secondary shelf. The set is sterile, not made with DEHP, and cased 100 at a time for infusion area stock.
Features and Benefits
Set Design
- Tubing: low-sorbing line material
- Bag Access: non-vented needle-free valve access port
- Connector: fixed male luer lock with hanger
Set Measures
- Drop Factor: 20 drop
- Length: 31 in.
- Fluid Path: 8 mL priming volume
- Material Note: not made with DEHP
Product Specifications
Set Details
- Set Type: secondary administration set, non-vented, low sorbing
- Sterility: sterile fluid path
- Drop Factor: 20 drop
Packaging
- Package Contents: 100 sets per case
Reference
- Manufacturer SKU: 10014881
- GTIN: 10885403221934
Browse the full IV Administration Sets range, or shop everything from BD.
Why Sorption Matters on a Short Little Secondary Line
A secondary infusion is a defined dose in a defined bag. Whatever the tubing absorbs is a dose the patient never receives. Low-sorbing material closes that quiet gap between the prescribed dose and the delivered one.
- Dose Fidelity – reduced absorption keeps the delivered dose closer to the prepared dose
- Minimal Prime Loss – the 8 mL path strands very little medication in the line
- Needle-Free Routine – valve access keeps the frequent secondary connection needle-free
- BD SmartSite Ecosystem – the set matches BD's needle-free platform used for primary lines as well
Frequently Asked Questions
What is this low-sorbing secondary set used for?
It is used for secondary IV infusions of medications where low-sorbing tubing is preferred to limit drug loss to the line.
What are this set's key measures?
A 20 drop factor, 31 in. length and a compact 8 mL priming volume, in low-sorbing tubing.
How is this product sold?
It is sold as one case: 100 sets per case. The listed price is for the complete case, with the full count breakdown in the specifications above.
Who uses this low-sorbing secondary set?
Infusion services giving medications whose dose accuracy suffers when standard tubing absorbs the drug.
Is this the genuine BD product?
Yes. MedicalEx lists this low-sorbing secondary set under its real BD manufacturer SKU (10014881), so the item that arrives matches the manufacturer's own catalog entry.
What does low-sorbing mean?
The tubing material is selected to absorb less of the infused medication, so more of the prepared dose reaches the patient.