Description
The Beckman Coulter DxH 500 Hematology Analyzer delivers a full five-part differential for low-volume laboratories that cannot justify a high-throughput line. It processes 60 samples per hour from open vials on as little as 12 microliters of blood, so small labs and clinics keep CBC testing in house instead of sending samples out and waiting on reference lab turnaround.
- Five-part differential – complete CBC with NE, LY, MO, EO and BA results
- 12 µL sample volume – venous and micro-collected samples suit pediatric and difficult draws
- 60 samples per hour – open vial sampling keeps benchtop workflow moving
- Three-reagent system – the full reagent set changes in under five minutes
Benchtop Hematology Analyzer Built for Low-Volume Laboratories
Small laboratories face a familiar squeeze: clinicians expect an in-house differential, yet sample volumes rarely justify a floor-standing analyzer. This benchtop system answers that gap with a compact 11 by 17 inch footprint and an integrated computer, so it fits the bench space a low-volume lab actually has. Open vial sampling accepts venous and micro-collected specimens, and the pre-dilute mode works from 20 microliters for the smallest draws.
Daily operation is built around speed and low upkeep. All three reagents change in under five minutes, the touch interface reaches any command in three touches or fewer, and a handheld 2D barcode reader speeds sample identification. Results store up to 30,000 patient records onboard, and serial plus Ethernet connections feed the laboratory information system.
Features and Benefits
Sample Handling
- Open vial sampling – run venous or micro-collected tubes without cap piercing hardware
- Micro-volume aspiration – 12 µL for standard samples and 20 µL in pre-dilute mode
Reagent System
- Three reagents only – DxH 500 Lyse 500 mL, DxH 500 Cleaner 500 mL and DxH Diluent 10 L
- Reduced reagent consumption – Beckman Coulter states up to 50 percent less reagent usage
- Cleaner formulation profile – reagents are cyanide free, azide free and formaldehyde free
Workflow and Connectivity
- Touch driven interface – every command is reachable within three touches
- LIS connectivity – serial RS-232 and Ethernet ports link results to the laboratory system
- Onboard storage – holds up to 30,000 patient results for review and retrieval
Product Specifications
Performance
- Throughput: 60 samples per hour
- Sampling Mode: Open vial
- Sample Volume: 12 µL venous or micro-collected, 20 µL pre-dilute
- Parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, plus the five-part differential NE, LY, MO, EO and BA in percent and absolute counts
Physical and Power
- Dimensions: 270 mm W x 430 mm D x 406 mm H (11 in x 17 in x 16 in)
- Weight: 11.4 kg (25.1 lb)
- Power: Under 120 W, 100 to 240 VAC, 50/60 Hz
- Data Storage: 30,000 patient results
Ordering Information
- Manufacturer: Beckman Coulter
- Packaging: 1 each
Browse the full Hematology Analyzers range, or shop everything from Beckman Coulter.
Why Laboratories Choose the DxH 500
The DxH 500 suits clinics and small hospital laboratories that need a genuine five-part differential without dedicating floor space or high-volume service contracts. Its micro-volume sampling and fast reagent changes keep a small team productive through the day.
- Faster answers for patients – in-house differentials return results the same visit instead of after reference lab transit
- Lower draw burden – 12 µL aspiration supports pediatric and geriatric patients with limited sample volume
- Compact bench fit – a differentiator over floor-standing systems, the integrated design needs just an 11 by 17 inch footprint
- Simple upkeep – three reagents changed in under five minutes reduce technologist time at the bench
Manuals and Troubleshooting Guides
Frequently Asked Questions
What sample types does this analyzer accept?
It samples from open vials using venous or micro-collected whole blood. Standard aspiration is 12 microliters, and a pre-dilute mode works from 20 microliters when only a small volume is available.
How many samples can it run per hour?
Throughput is 60 samples per hour in open vial mode. That pace fits low-volume laboratories running routine CBC work through the day.
Which reagents does it use?
The system runs on three reagents: DxH 500 Lyse in a 500 mL bottle, DxH 500 Cleaner in a 500 mL bottle and DxH Diluent in a 10 L container. Beckman Coulter states the full set changes in under five minutes.
How much bench space does it need?
The analyzer measures 270 mm wide by 430 mm deep by 406 mm high and weighs 11.4 kg. The integrated computer keeps the footprint compact for benchtop placement.
Can results go to our laboratory information system?
Yes, the analyzer offers serial RS-232 and Ethernet connectivity for the laboratory information system. It also stores up to 30,000 patient results onboard for later review.
Is this the cap piercing version?
No, this configuration is the open vial model without cap piercing. Laboratories that need closed tube sampling should look at the DxH 520 configuration instead.