null
BR Surgical

BR Surgical Townsend Mini Biopsy Punch - Rotating Head - 2.3 x 4.2 mm Bite - 9 3/4 Inch

(No reviews yet) Write a Review
$744.99
SKU:
BR70-62405-MN
MPN:
BR70-62405-MN
Shipping:
FREE standard shipping (contiguous US)
$744.99
Fast Delivery
Fast Delivery
Most ship in 1–2 days
Shipping
$50+ Ship Free
Flat $6.95
30-Day Returns
30-Day Returns
No questions asked
Secure Payment
Secure Payment
100% safe checkout

Description

The Townsend Mini Biopsy Punch from BR Surgical is built for cervical biopsy sampling with a rotating mini punch head. TOWNSEND MINI Biopsy Punch, rotating, 2.3x4.2mm, 9 3/4" GOLD SERIES.

  • Pattern: Rotating head, mini pattern
  • Size: 2.3 x 4.2 mm bite, 9 3/4 inch shaft
  • Rotating Head: Punch head rotates to orient the bite without twisting the shaft
  • Mini 2.3 x 4.2 mm Bite: Smaller bite for small lesions and scarred sites
  • 9 3/4 Inch Shaft: Standard reach for colposcopic biopsy
  • Material: Stainless steel

Townsend Mini Biopsy Punch - A Rotating Townsend Mini Biopsy Punch

The Townsend mini punch takes a smaller bite than the standard Tischler patterns, and this model rotates its head so the bite can be oriented to the lesion without turning the whole instrument. The 2.3 x 4.2 mm bite suits smaller lesions and a scarred cervix where a full-size bite is more than the site allows. The 9 3/4 inch shaft is the standard reach for cervical biopsy under colposcopic view. The manufacturer's device record describes this catalog number as follows: TOWNSEND MINI Biopsy Punch, rotating, 2.3x4.2mm, 9 3/4" GOLD SERIES

Features and Benefits

  • Rotating Head: Punch head rotates to orient the bite without twisting the shaft
  • Mini 2.3 x 4.2 mm Bite: Smaller bite for small lesions and scarred sites
  • 9 3/4 Inch Shaft: Standard reach for colposcopic biopsy
  • Reusable Construction: Solid stainless steel build made to be cleaned and sterilized between cases
  • Pattern Fidelity: Ground and finished to the Townsend Mini Biopsy Punch pattern so it handles like the instrument it replaces

Product Specifications

Design

  • Pattern: Rotating head, mini pattern
  • Size: 2.3 x 4.2 mm bite, 9 3/4 inch shaft
  • Material: Stainless steel

Use and Care

  • Sterility: Supplied non-sterile, sterilize before use
  • Reprocessing: Clean and sterilize between cases following the facility instrument protocol
  • Sold As: Each
  • Warranty: Lifetime instrument warranty from BR Surgical, covering defects in material and workmanship for the life of the product

Browse related instruments in our Surgical Instruments department and the BR Surgical brand page for the full line.

Why Choose the Townsend Mini Biopsy Punch?

Facilities stock the Townsend Mini Biopsy Punch when they want the correct pattern from the manufacturer of record, in a build that holds up to daily reprocessing. It arrives non-sterile and ready for the tray after standard preparation.

  • Sold as Each: One instrument per order unit for straightforward tray stocking and reordering
  • Tray-Ready Pattern: A true Townsend Mini Biopsy Punch pattern that drops into existing sets without changing technique
  • Reprocessing Friendly: Stainless steel construction stands up to routine cleaning and steam sterilization
  • Consistent Sourcing: One catalog number from BR Surgical, the manufacturer of record for this instrument
  • Lifetime Coverage: Backed by the BR Surgical lifetime instrument warranty against defects in material and workmanship

Frequently Asked Questions

Why a rotating punch?
Rotating the head lets the clinician align the bite to the lesion angle while the shaft stays steady, which gives cleaner sample orientation. Fixed punches require rotating the whole instrument.
When is the mini chosen over a standard Tischler?
The mini bite takes a smaller sample, which suits small lesions, a scarred cervix, or sites where a full bite would take more tissue than needed. It is the Townsend mini pattern in the biopsy range.
Is it sold as a single instrument?
Yes, it is sold as each, one instrument per order unit, under a single catalog number.
Is it sterile on arrival?
No, it is supplied non-sterile and is cleaned and sterilized before use under the facility instrument protocol. It is a reusable instrument made for repeated reprocessing.
What warranty covers it?
BR Surgical covers this instrument under its lifetime instrument warranty against defects in material and workmanship for the life of the product. The full warranty statement is in the specifications above.
View AllClose

Warranty Information

BR Surgical warrants this instrument to be free from defects in material and workmanship for the life of the product, covering repair or replacement under the manufacturer's lifetime instrument warranty.
View AllClose

0 Reviews

View AllClose

Explore our wide range of medical products, enjoy hassle-free shopping, and take advantage of our exclusive offers. Free shipping on orders over $50! Need assistance? Contact our friendly customer support team at (800) 494-5750. Happy shopping!