Description
The MedSource DialySafe Hemodialysis Connector is a sterile, split-septum valve made for hemodialysis procedures, with a flow rate over 600 mL per minute and a priming volume of only 0.085 mL. Its needle-free, swabbable design keeps access closed and cleanable between treatments.
- High Flow Rate – over 600 mL per minute for dialysis circuits
- Low Priming Volume – 0.085 mL valve volume
- Copolyester Valve – clear, durable medical plastic housing
A High-Flow Split-Septum Valve Built for Dialysis
Dialysis circuits move blood fast, so the valve's flow rating and linear path are the headline numbers here. The housing is clear and durable medical plastic, and the configuration is neutral to avoid disturbing the circuit at connection changes.
The connector is sterile, not made with natural rubber latex and sold in boxes of 100. It is a single-patient dialysis accessory, not a general IV connector substitute.
Features and Benefits
- Flow Rate: The valve supports a flow rate over 600 mL per minute.
- Priming Volume: The priming volume is 0.085 mL.
- Valve Material: The valve is copolyester, a clear and durable medical plastic.
- Sterility: The connector is sterile.
- Latex Content: The connector is not made with natural rubber latex.
Product Specifications
Product Details
- Flow Rate: > 600 ml/min
- Priming Volume: 0.085 mL
- Valve Material: Copolyester
- Sterile: Yes
- Latex Content: Not made with natural rubber latex
Browse the full IV Connectors & Caps range, or shop everything from MedSource International.
Why Choose the DialySafe Hemodialysis Connector
Dialysis units need a connector rated for their flow, not a general-purpose valve pushed past its design. DialySafe is specified for the circuit it serves.
- Dialysis-Rated Flow – over 600 mL per minute matches circuit demands
- Minimal Volume – 0.085 mL priming volume keeps the circuit tight
- Closed Access – the swabbable split septum stays closed between uses
- Box Packaging – boxes of 100 suit dialysis unit stocking
Manuals and Troubleshooting Guides
Frequently Asked Questions
Does it contain natural rubber latex?
No. The DialySafe Hemodialysis Connector is not made with natural rubber latex, as stated in the specifications on this page.
How is the DialySafe Hemodialysis Connector packaged?
It is sold in boxes of 100. The manufacturer's item numbers for this listing are MS-83512.
Where is the DialySafe Hemodialysis Connector used?
It is used in hemodialysis units for access on dialysis circuits. Dialysis units need a connector rated for their flow, not a general-purpose valve pushed past its design.
What flow rate does it support?
The DialySafe valve is rated at a flow rate over 600 mL per minute, with a priming volume of 0.085 mL. Those figures are sized for hemodialysis circuits.
Is it needle-free?
Yes. The split-septum valve is swabbable and needle-free, and the connector is sterile and not made with natural rubber latex.