Description
The Hertel Exophthalmometer is a precision instrument for exophthalmos readings, measuring from the outer orbital rim to the apex of the cornea with integral refraction mirrors and millimeter scales for left and right readings. Its supports rest against the temporal orbital walls so the zero mark sits in the plane of the resting points.
- Hertel geometry: Reads from the orbital rim to the corneal apex
- Integral mirrors: Refraction mirrors with millimeter scales for both reading halves
- Calibrated zero: Zero mark sits in the plane of the support resting points
The Hertel Standard for Exophthalmos Measurement
Exophthalmos readings only compare across visits when the instrument geometry is fixed, and the Hertel design fixes it. The measurement basis is the distance from the outer orbital rim, the orbital wall, to the apex of the cornea, the standard for conditions such as exophthalmic goiter. The instrument's supports are placed against the two temporal orbital walls so the orbital rim contacts the deepest point of the supports. Integral refraction mirrors with millimeter scales serve the left-hand and right-hand reading halves. The scales are calibrated so the zero mark is located in the plane of the resting points of the supports, which keeps the reference plane consistent from patient to patient. For thyroid eye disease monitoring and orbital assessment, this is the reference instrument format.
Features and Benefits
- Hertel geometry: Reads from the orbital rim to the corneal apex
- Integral mirrors: Refraction mirrors with millimeter scales for both reading halves
- Calibrated zero: Zero mark sits in the plane of the support resting points
Product Specifications
Instrument
- Type: Hertel exophthalmometer
- Measurement basis: Outer orbital rim to apex of cornea
- Scales: Millimeter scales, left and right halves, integral refraction mirrors
Product Details
- Manufacturer: Good-Lite Company
- Manufacturer SKU: 521500
- Packaging: EA / 1
Explore more in Professional Use or Shop more Good-Lite.
Why Choose This Hertel Exophthalmometer
Proptosis monitoring is a numbers game played over months. The Hertel reference geometry keeps those numbers comparable at every visit.
- Repeatable readings: Fixed reference plane for visit-to-visit comparison
- Clinical standard: The Hertel format orbital assessment is built on
- Both eyes, one instrument: Left and right scales with integral mirrors
Frequently Asked Questions
What does an exophthalmometer measure?
It measures exophthalmos, the protrusion of the eye, read from the outer orbital rim to the apex of the cornea.
How are the supports placed?
The supports are placed against the two temporal orbital walls so the orbital rim contacts the deepest point of the supports.
How are readings taken?
Integral refraction mirrors with millimeter scales serve the left-hand and right-hand reading halves.
What conditions is it used for?
It is used for precise exophthalmos readings, for example in exophthalmic goiter and thyroid eye disease assessment.
How is this product packaged?
It is sold in the manufacturer's standard packaging for the selected configuration, EA / 1, as shown in the product specifications.