Description
The Invacare microAIR MA600 is an alternating pressure and low air loss mattress system for patients at medium to high risk of pressure injuries. Its 3-in-1 therapy cycle supports prevention and treatment from stage I through stage IV.
- 3-in-1 alternating pressure supports 2/3 of the body at any time
- Low air loss manages moisture and heat at the skin surface
- HeelSense technology reduces pressure on vulnerable heels
- Eight adjustable comfort settings to match the patient
- Audio and visual alarms for low pressure conditions
Pressure injuries develop where load, heat and moisture stay on the same skin for too long, so an effective surface has to move all three. The MA600 cycles air through its cells in a 3 to 1 pattern, so two thirds of the body stays supported while one third unloads and reperfuses. Low air loss airflow cools and dries the skin surface through the vapor permeable cover. HeelSense technology gives the heels, the most common injury site, their own gentler pressure profile. Eight comfort settings let staff tune support to the patient rather than to a single factory setting.
Features and Benefits
Therapy Modes
The cycle pattern is what separates a therapeutic surface from a simple air bed.
- 3-in-1 alternating cycle keeps 2 of 3 cells inflated under the patient
- HeelSense technology lowers pressure in the heel zone
- Max Inflate mode firms the surface quickly for care and transfers
Cover and Monitoring
Covers and alarms carry the therapy when nobody is watching the pump.
- Quilted nylon top cover is vapor permeable and low shear
- Non-slip base cover keeps the mattress placed on the bed frame
- Audio and visual alarms warn staff about low pressure or faults
Product Specifications
- Model: MA600 complete system
- Dimensions: 36 in W x 80 in L x 8 in H
- Weight capacity: 500 lb
- Therapy: Alternating pressure with low air loss, 3-in-1 cycle
- Flow rate: 10 LPM
- Alarms: Audio and visual
- Warranty: 1 year on the cover and mattress, 1 year on the power unit
- HCPCS: E0277
- Packaging: Sold as EA/1 (each), exactly as packaged by Invacare.
Browse the full Air Mattress Systems range, or shop everything from Invacare.
Why Choose the Invacare microAIR MA600?
Basic alternating pads cycle air but ignore heels and moisture. This system combines the cycle with low air loss and heel offloading in a single Invacare model number.
- Cell-in-cell safety – the mattress design helps stop the patient bottoming out during a power failure, so therapy failure does not become a skin emergency, which matters on night shifts
- Heel-specific therapy – HeelSense targets the injury site clinicians worry about most, so the heels get their own pressure profile, which a uniform cycle cannot give
- Complete system in one box – mattress and power unit arrive together under one model number, so there is no separate pump order to delay a start of care, which speeds up discharge setups
Frequently Asked Questions
Who is the MA600 for?
It is designed for patients at medium to high risk of pressure injuries, covering stages I to IV, at home or in a care facility.
What is the weight limit?
The system supports patients up to 500 lb on its 36 in wide surface.
Does the pump come with it?
Yes. This listing is the complete system, mattress and power unit. The MA600P is Invacare's pump-only model for replacing a power unit on an existing mattress.
What happens in a power failure?
The cell-in-cell mattress design helps prevent the patient bottoming out if power is lost.
What warranty applies?
The limited warranty covers the cover and mattress for 1 year and the power unit for 1 year.