Description
LCCS Disposable RF Electrodes give pain practices a single use electrode for temperature controlled RF and pulsed RF treatments, matched to the cannula lengths already on the tray. Each electrode is surgical grade stainless steel in a 27G profile, in 50mm, 100mm and 150mm lengths that pair with standard cannula sizes. Boxes of 5 keep procedure rooms stocked without tying up capital in reusable inventory.
- Single Use Format – a fresh sterile pathway for every case, with no reprocessing between patients.
- Three Lengths – 50mm, 100mm and 150mm electrodes match the cannula lengths used across RF procedures.
- Any Gauge Cannula Fit – the electrodes work with RF cannulas of any gauge.
- Surgical Grade Steel – stainless construction holds up through long lesioning cycles.
Disposable Electrodes for Temperature Controlled and Pulsed RF
Temperature controlled radiofrequency and pulsed RF treatments run through an electrode placed inside the cannula, and that electrode has to match the cannula length exactly to position the sensing point correctly. These disposable electrodes come in 50mm, 100mm and 150mm lengths that correspond to the standard cannula sizes in this catalog. They are constructed from high quality surgical grade stainless steel for dependable performance through the full treatment cycle. The 27G profile fits RF cannulas of any gauge, so one electrode family serves the whole cannula inventory. Because they are disposable, there is no sterilization turnaround between cases and no wear related drift in a reprocessed tip. Adaptor cables are available to connect the electrodes to most major RF generators.
Features and Benefits
Electrode Construction
- Surgical Grade Stainless Steel – high quality steel construction for consistent energy delivery.
- 27G Profile – a slim electrode that fits RF cannulas of any gauge.
- Single Use – disposable format removes reprocessing and wear concerns.
Length Options
- 50mm, 100mm and 150mm – lengths correspond to standard cannula sizes for correct tip positioning.
- Generator Adaptors – compatible adaptor cables are available for most major RF generators.
Product Specifications
Product Details
- Brand: LCCS Medical
- Electrode Gauge: 27G
- Lengths: 50mm, 100mm, 150mm
- Use Style: Disposable, single use
Materials and Packaging
- Material: Surgical grade stainless steel
- Packaging: Box of 5
See all Syringes and Needles or Shop more LCCS Medical Products.
Why Choose LCCS Medical?
Disposable electrodes trade a small per case cost for zero reprocessing labor and a like new tip on every patient. For practices running back to back RF lists, that reliability is worth more than the savings from reprocessing.
- No Reprocessing Queue – cases never wait on sterilization turnaround for an electrode.
- Consistent Tip Condition – every patient gets an unworn electrode, so temperature readings stay dependable.
- Whole Inventory Fit – one 27G family serves cannulas of every gauge in the practice.
- Simple Stocking – boxes of 5 in three lengths are easy to par and reorder.
Manuals and Troubleshooting Guides
Frequently Asked Questions
What lengths do the disposable electrodes come in?
They are offered in 50mm, 100mm and 150mm, matched to standard RF cannula lengths.
Can these electrodes be sterilized and reused?
No. The disposable electrodes are single use and cannot be sterilized. A reusable version is available in the same lengths.
Which cannulas do they fit?
The 27G electrodes are designed to be used with RF cannulas of any gauge.
What treatments are they used for?
They are used with RF cannulas in temperature controlled radiofrequency and pulsed RF treatments.
How many electrodes are in a box?
Each box contains 5 electrodes of a single length.