Description
Moog CURLIN 380 Series Administration Set is the current generation of CURLIN infusion tubing, built for the CURLIN 8000, CURLIN 6000 and CURLIN PainSmart pumps used across home infusion and hospital programs. Every configuration is non-DEHP PVC with integral free-flow protection, so the line stays safe if it is ever removed from the pump. Pharmacy and nursing teams pick the exact build each therapy needs, from a plain set to filtered sets with an add-on check valve.
- Five real configurations – Plain, 1.2 micron filtered, and 0.2 micron filtered builds, with or without an add-on check valve.
- Non-DEHP PVC – Every set is non-DEHP and not manufactured with rubber latex, a safer default for sensitive patients.
- Integral free-flow protection – The set design guards against free flow when the tubing leaves the pump mechanism.
- Case of 20 – Supplied 20 sets to a case so programs can stock a full therapy cycle at once.
CURLIN Infusion Sets Matched to the Pump and the Therapy
The 380 Series replaced the older CURLIN set line with a consistent 2.5 m platform for filtered builds and a shorter 2.4 m plain set. Filtered configurations carry a vented, air-eliminating, low-protein binding filter in either 1.2 micron or 0.2 micron, which suits lipid-bearing and fine-particle-sensitive infusions. The V configurations add an add-on check valve for lines that need backflow protection at the patient end. Priming volume is 3.6 mL on the plain set and 6.2 mL on the filtered builds, measured at 23 degrees C. Home infusion nurses loading a CURLIN pump for a week of home therapy get the same set geometry on every configuration, so training stays simple while the therapy dictates the filter choice.
Features and Benefits
Set Construction
- Non-DEHP PVC tubing – Moog builds every 380 Series set from non-DEHP PVC, and no set is manufactured with rubber latex.
- Integral free-flow protection – Protection is built into the set itself rather than added as a separate clamp step.
- Slide clamp and luer – Each set finishes in a standard luer with a slide clamp for manual control during setup.
Filter Options
- 1.2 micron vented filter – Air-eliminating and low-protein binding, sized for emulsions and standard filtered therapy.
- 0.2 micron vented filter – Finer air-eliminating filtration for therapies that spec a 0.2 micron set.
- Add-on check valve – The V builds add a check valve that resists backflow toward the pump.
Product Specifications
Compatibility
- For use with – CURLIN 8000, CURLIN 6000 and CURLIN PainSmart infusion pumps
- Spike – Non-vented bag spike on every configuration
Configuration Details
- 380-4114 – No filter, 93 in (2.4 m) length, 3.6 mL priming volume
- 380-4128 – 1.2 micron vented filter, 99 in (2.5 m) length, 6.2 mL priming volume
- 380-4128V – 1.2 micron vented filter with add-on check valve, 99 in (2.5 m) length, 6.2 mL priming volume
- 380-4130 – 0.2 micron vented filter, 99 in (2.5 m) length, 6.2 mL priming volume
- 380-4130V – 0.2 micron vented filter with add-on check valve, 99 in (2.5 m) length, 6.2 mL priming volume
- Packaging – Case of 20 sets, packaging sold as listed
Browse the full range of IV Administration Sets for related products, or see everything from Moog in one place.
Why Choose the CURLIN 380 Series Set?
Programs standardize on one pump platform to keep training tight, and the set line has to cover every therapy that platform runs. The 380 Series does that with five builds that share one geometry, so a filter change never becomes a retraining event.
- One geometry, every therapy – Shared length and fittings across builds keep loading technique identical.
- Filter choice without compromise – 1.2 and 0.2 micron vented filters cover emulsion and fine filtration orders.
- Genuine Moog sets – Moog states that only CURLIN sets should be used in CURLIN pumps to hold the rated delivery accuracy.
- Free-flow protection built in – The safeguard travels with every set rather than depending on a separate accessory.
Manuals and Troubleshooting Guides
Frequently Asked Questions
Which pumps do these sets fit?
Moog lists the 380 Series sets for the CURLIN 8000, CURLIN 6000 and CURLIN PainSmart infusion pumps.
What is the difference between the 4128 and 4130 builds?
The 4128 builds carry a vented 1.2 micron filter, while the 4130 builds carry a vented 0.2 micron filter. Both filters are air-eliminating and low-protein binding.
What does the V suffix add?
The V configurations add an add-on check valve at the patient end of the set for backflow protection.
Are the sets DEHP free?
Yes. Moog states that all CURLIN administration sets are non-DEHP PVC and are not manufactured with rubber latex.
How many sets come in a case?
Each configuration is supplied 20 sets to a case, and the case is the package sold on this listing.
Can I use a different brand of set in a CURLIN pump?
Moog directs users to use only CURLIN administration sets in CURLIN pumps, because other sets can alter delivery accuracy.