Description
The Nikomed Nikosurg ESU Grounding Pads, the Nikosurg grounding pad, is a disposable pregelled neutral electrode line for monopolar electrosurgery, in standard, split and prewired split versions from Nikomed, made for safe return of electrosurgical current in monopolar procedures on adults and children. Operating room teams and surgical centers reach for the Nikosurg grounding pad when a return electrode whose contact quality the generator can actually monitor, case after case matters more than improvising with the wrong supply. The Nikosurg grounding pad keeps the routine simple, so attention stays on the work itself instead of the equipment.
- Standard 2407N – The unsplit pad for generators without contact quality monitoring, 100 to a box, cable supplied separately.
- Split 2408 – The split pad pairs with REM-style monitoring so the generator watches contact quality throughout the case.
- Prewired 2508 – The split pad arrives with its 3 m REM cable attached, 50 to a box, ready to plug in.
- Overlapping Gel – Hydrogel overlaps the conductive foil edge, the construction that guards against edge burns.
- Rounded Active Geometry – Rounded geometry spreads current evenly across the 171 sq cm pad.
About This Nikosurg ESU Grounding Pads
Nikomed supplies this nikosurg ESU Grounding Pads under part number the Nikosurg pad configurations 2407N, 2408 and 2508, so what is described here is exactly what arrives. For this Nikosurg grounding pad, every pad is a universal adult and pediatric design with rounded active geometry and overlapping gel, and the split versions work with contact quality monitoring systems such as REM. Day to day, the circulating nurse seats the pad on a well-vascularized site before the case, connects the cable where the version requires one, and the generator monitors contact from there. It is sold as listed: pads in the configuration selected, 100 per box for 2407N and 2408 or 50 per box for the prewired 2508, sold per box. Consistent packaging and the stable part number the Nikosurg pad configurations 2407N, 2408 and 2508 make repeat ordering simple for busy supply managers.
Features and Benefits
Pad Versions
- Standard 2407N – The unsplit pad for generators without contact quality monitoring, 100 to a box, cable supplied separately.
- Split 2408 – The split pad pairs with REM-style monitoring so the generator watches contact quality throughout the case.
- Prewired 2508 – The split pad arrives with its 3 m REM cable attached, 50 to a box, ready to plug in.
Safety Construction
- Overlapping Gel – Hydrogel overlaps the conductive foil edge, the construction that guards against edge burns.
- Rounded Active Geometry – Rounded geometry spreads current evenly across the 171 sq cm pad.
- Universal Sizing – One pad size is rated for both adults and pediatrics, simplifying OR stocking.
Product Specifications
Construction
- Backing: Non-woven fabric
- Conductive Material: Aluminium
- Gel: Hydrogel, 0.50 mm thick
- Adhesive: Medical acrylic adhesive
- Type: Disposable, pregelled, non-sterile
- Materials: Latex and PVC free
Performance and Packaging
- Pad Size: 15.7 x 13.0 cm max, 171 sq cm total area
- Impedance: Under 1.5 ohms, 200 to 5000 kHz
- Thermal: Max temperature rise under 6 deg C at 700 mA over 60 sec
- 2508 Cable: 3 m, REM connector
- Shelf Life: 36 months unopened
- Storage: Plus 5 to plus 30 deg C
Browse the full Electrosurgery range, or shop everything from Nikomed.
Why Choose This Nikosurg ESU Grounding Pads
Generic alternatives make the same promises, yet the Nikosurg grounding pad pairs them with Nikomed quality control and a published specification sheet. For this Nikosurg grounding pad, nikomed publishes the full neutral electrode data sheet, including a maximum temperature rise under 6 degrees C at 700 mA and impedance under 1.5 ohms across 200 to 5000 kHz. For a supply room stocking the Nikosurg pad configurations 2407N, 2408 and 2508, that record matters.
- Monitored Contact – Split versions let the generator verify pad contact continuously, the control that prevents return-site burns.
- One Pad, Every Patient – A universal adult and pediatric rating removes size guesswork from case setup.
- Published Safety Data – Thermal rise, impedance and biocompatibility results are published per version, ready for any value analysis review.
- Prewired Speed – The 2508's attached cable removes a connection step and a separate cable purchase from every case.
Manuals and Troubleshooting Guides
- 2407-N Technical Data Sheet
- 2408 Technical Data Sheet
- 2508 Technical Data Sheet
- Neutral Electrodes Instructions for Use
Frequently Asked Questions
What is the Nikomed Nikosurg ESU Grounding Pads used for?
As the Nikosurg grounding pad, it is a disposable pregelled neutral electrode line for monopolar electrosurgery, in standard, split and prewired split versions, used for safe return of electrosurgical current in monopolar procedures on adults and children. It gives surgical teams a pregelled neutral electrode in standard, split and prewired split versions for monopolar electrosurgery.
What exactly ships when I order?
The listing is sold as listed: pads in the configuration selected, 100 per box for 2407N and 2408 or 50 per box for the prewired 2508, sold per box. The manufacturer part number is the Nikosurg pad configurations 2407N, 2408 and 2508, so checking an order against this page takes seconds.
Who is this product made for?
Operating room teams and surgical centers are the typical buyers of the Nikosurg grounding pad, using it for safe return of electrosurgical current in monopolar procedures on adults and children. It suits both stocked supply rooms and smaller practices that order the Nikosurg grounding pad as needed.
Which pad works with a contact quality monitoring system?
The manufacturer's neutral electrode instructions are explicit: when the electrosurgical unit offers a contact quality monitoring system such as REM, always use a split electrode. That means the 2408 or the prewired 2508 on this listing, never the standard 2407N.
Where can I find the full specifications?
The Product Specifications section on this page lists the grounded manufacturer details for the Nikosurg pad configurations 2407N, 2408 and 2508, including the part number and package configuration. The Features and Benefits section explains what those details mean for the Nikosurg grounding pad in daily use.
Who stands behind this product?
Yes, the Nikosurg pad configurations 2407N, 2408 and 2508 is a genuine Nikomed item, entered under the manufacturer's own part number. Nikomed manufactures its electrodes and surgical accessories in Hatboro, Pennsylvania, is ISO 13485 certified and FDA registered, and publishes a technical data sheet for every electrode it sells, and that backing covers the Nikosurg grounding pad on this listing.