Description
Nonin 6000C Disposable Cloth SpO2 Sensors with Stretch Tear-Resistant Wrap, Four Sizes, Box of 24
The Nonin 6000C Disposable Cloth Sensors build the sensor, cable and adhesive cloth wrap into one stretch, tear-resistant unit. The cloth format is made for extended monitoring and for hard to fit patients such as infants and neonates, keeping the sensor in proper position.
- Stretch, tear-resistant cloth for secure extended wear
- Integrated sensor, cable and adhesive wrap design
- Four sizes, adult, pediatric, infant and neonatal
- PureLight technology in a disposable format, box of 24
6000C Disposable Cloth Sensors for Extended Monitoring
Extended monitoring exposes the weakness of rigid sensors, because hours of wear punish both skin and placement. The cloth construction answers with a stretch, tear-resistant wrap that moves with the patient while holding the sensor in position. The manufacturer designed the line for patients who are hard to fit, calling out infants and neonates whose small digits defeat standard formats. Each disposable unit integrates the sensor, its cable and the adhesive cloth wrap, so there are no separate wraps to stock or lose. PureLight LED technology provides the signal quality behind the line's declared accuracy. Four sizes in boxes of 24 let a department standardize on cloth disposables across its whole census.
Features and Benefits
Cloth Construction
- Stretch and Tear Resistant – the cloth wrap flexes with the patient without giving way.
- Extended Wear Comfort – soft cloth suits the long monitoring sessions disposables are chosen for.
- Integrated Unit – sensor, cable and wrap arrive combined in one piece.
Coverage
- Four Patient Sizes – adult, pediatric, infant and neonatal versions.
- Hard to Fit Focus – designed for infants, neonates and other difficult placements.
- Box of 24 – department friendly packaging for routine restocking.
Product Specifications
Performance
- SpO2 Accuracy: 70 to 100% within 3 digits for neonates and 2 digits for adults (Arms)
- Low Perfusion Accuracy: 70 to 100% within 2 digits (Arms)
- Patient Sizes: Adult 6000CA, pediatric 6000CP, infant 6000CI, neonatal 6000CN
- Sensor Technology: PureLight LED, disposable cloth
- Use: Single patient use, extended monitoring
Configuration
- Package: Box of 24 sensors
- Compatibility: Nonin pulse oximeters per the manufacturer Sensor Compatibility Guide
- Latex: Not made with natural rubber latex
- Construction: Sensor, cable and adhesive cloth wrap integrated
See all Oximeter Accessories for the full range, or Shop more Nonin Products for the complete line.
Why Extended Monitoring Programs Choose the 6000C Cloth Line
Long sessions fail at the sensor interface more often than at the monitor. A cloth wrap that stretches, resists tearing and stays positioned protects the data quality of the whole study.
- Position That Persists – the cloth wrap keeps the sensor aligned through hours of wear.
- Comfort for Small Patients – soft cloth suits infants and neonates during extended monitoring.
- Nothing Separate to Stock – the integrated wrap ends the search for matching adhesive wraps.
- PureLight Signal – disposable convenience without leaving the PureLight standard.
Manuals and Troubleshooting Guides
Frequently Asked Questions (FAQs)
What makes cloth sensors different from foam sensors?
The 6000C line uses a stretch, tear-resistant cloth wrap instead of microfoam. It is positioned for extended monitoring and hard to fit patients such as infants and neonates.
What sizes are stocked?
Adult 6000CA, pediatric 6000CP, infant 6000CI and neonatal 6000CN. Choose the patient size from the option list.
How many are in a box?
Each size ships 24 sensors per box, and this listing is priced per box. All four sizes share the same box quantity.
Are the sensors single use?
Yes. Each unit is a single patient disposable with the sensor, cable and cloth wrap integrated.
Which monitors accept them?
Nonin oximeters compatible with PureLight disposable sensors, per the manufacturer Sensor Compatibility Guide. Compatibility is stated per monitor model in that document.