Description
Nonin 8000FC Fiber Optic SpO2 Sensor for Adult and Pediatric Patients in 20 and 30 Foot Cable Lengths
The Nonin 8000FC Fiber Optic Sensor carries light instead of electricity to adult and pediatric patients in MRI environments. Paired with the Model 7500FO monitor, it keeps metallic components out of the scan field while saturation monitoring continues.
- Fiber optic sensing for MRI suite use with the Model 7500FO
- Adult and pediatric patient application
- Declared accuracy within 2 digits from 70 to 100 percent
- 20 foot and 30 foot cable lengths for scan room layouts
8000FC Fiber Optic Sensor for MRI Suite Oximetry
Conventional sensor cables cannot enter the MRI field, so fiber optic sensors transmit the measurement light along a fiber path instead. This model serves adult and pediatric patients and connects to the Model 7500FO fiber optic tabletop monitor. Long cable options of 20 and 30 feet let the monitor stay positioned for the suite layout while the sensor reaches the patient in the bore. Accuracy is declared within 2 digits across the 70 to 100 percent saturation range, matching the monitoring standard of the platform. Application uses fiber optic sensor wraps, with finger and toe wrap versions stocked separately. The manufacturer backs the fiber optic sensor line with a 3-month warranty.
Features and Benefits
MRI Design
- Fiber Optic Path – light travels by fiber, keeping metallic parts away from the patient site.
- 7500FO Pairing – specified for the Model 7500FO fiber optic tabletop monitor.
- Long Cable Options – 20 and 30 foot lengths suit scanner room geometry.
Performance
- Within 2 Digits – declared saturation accuracy from 70 to 100 percent.
- Adult and Pediatric – one sensor model spans both patient groups.
- Wrap Application – fiber optic wraps secure the sensor at the site.
Product Specifications
Performance
- SpO2 Accuracy: 70 to 100% within 2 digits (Arms)
- Patient Group: Adult and pediatric
- Sensor Technology: Fiber optic SpO2 sensor, reusable
- Intended Monitor: Nonin Model 7500FO
Configuration
- Cable Lengths: 20 ft and 30 ft options
- Application Aids: 8000FW finger wrap and 8000TW toe wrap, sold separately
- Package: Sold individually
- Warranty: 3-month manufacturer warranty
See all Oximeter Accessories for the full range, or Shop more Nonin Products for the complete line.
Why MRI Suites Specify the 8000FC Fiber Optic Sensor
Imaging suites cannot borrow the ward's sensors, and unsupported workarounds put both patients and studies at risk. The manufacturer specified fiber optic path is the defensible way to monitor saturation during scans.
- Suite Specified Hardware – fiber optic sensing is the declared route for the 7500FO platform.
- Reach Across the Room – 30 foot cable options cover bore to console distances.
- Covers Both Populations – one model serves the suite's mixed patient list.
- Standard Accuracy – the 2 digit declaration matches the monitoring platform.
Manuals and Troubleshooting Guides
Frequently Asked Questions (FAQs)
Why does MRI monitoring use fiber optic sensors?
Standard cables contain metallic components that cannot be used in the scanner's magnetic field. Fiber optic sensors carry light instead of electrical signals at the patient site.
Which monitor does the 8000FC work with?
It is specified for the Nonin Model 7500FO fiber optic tabletop pulse oximeter. That monitor is listed separately in this catalog.
What cable lengths are available?
Choose 20 foot or 30 foot versions from the option list. The longer cable suits suites where the monitor sits farther from the bore.
How is the sensor held in place?
Fiber optic sensor wraps secure it, with the 8000FW finger wrap and 8000TW toe wrap sold in packs of two. Both wraps are listed in this catalog.
What warranty applies?
The manufacturer states a 3-month warranty for the fiber optic sensor line. The operator manual gives the full terms.