null
Nonin

Nonin 8000Q2 PureLight Reusable Ear Clip SpO2 Sensor for Monitoring When Fingers Are Not Available

(No reviews yet) Write a Review
SKU:
6455-000
Shipping:
Calculated at Checkout
  • Nonin 8000Q2 PureLight Reusable Ear Clip SpO2 Sensor for Monitoring When Fingers Are Not Available
  • Nonin 8000Q2 PureLight Reusable Ear Clip SpO2 Sensor for Monitoring When Fingers Are Not Available
  • Nonin 8000Q2 PureLight Reusable Ear Clip SpO2 Sensor for Monitoring When Fingers Are Not Available
$346.99
Fast Delivery
Fast Delivery
Most ship in 1–2 days
Shipping
$50+ Ship Free
Flat $6.95
30-Day Returns
30-Day Returns
No questions asked
Secure Payment
Secure Payment
100% safe checkout

Description

Nonin 8000Q2 PureLight Reusable Ear Clip SpO2 Sensor for Monitoring When Fingers Are Not Available

The Nonin 8000Q2 Ear Clip Sensor moves oximetry to the ear when fingers are not the preferred application site. It applies quickly for spot checks and monitoring, with declared accuracy within 3 digits across the saturation range.

  • Ear clip application for patients whose digits are unavailable or unsuitable
  • Fast, easy application for spot checking
  • SpO2 accuracy within 3 digits from 70 to 100 percent
  • Low perfusion accuracy within 2 digits

8000Q2 Ear Clip Sensor for Alternative Site Oximetry

Digit sites fail for many reasons, from poor peripheral perfusion and edema to injury, dressings and patient preference. An ear clip gives clinicians a central, well perfused site that responds quickly to saturation changes. The manufacturer positions this sensor for monitoring when digits are not the preferred application site, and for fast spot checking. PureLight LED technology keeps the signal clean, and low perfusion accuracy is declared within 2 digits. The clip applies in seconds without wraps or adhesives, which suits rapid assessments and short monitoring windows. It connects to Nonin monitors across the tabletop and handheld ranges.

Features and Benefits

Alternative Site

  • Ear Lobe Application – a central site for patients whose fingers cannot be used.
  • Quick Clip On – applies in seconds with no wraps or tape.
  • Central Perfusion – ear sites often read when peripheral sites struggle.

Performance

  • Within 3 Digits – declared saturation accuracy across 70 to 100 percent.
  • Low Perfusion Strength – accuracy within 2 digits in low perfusion testing.
  • PureLight LEDs – clean spectrum output for PureSAT processing.

Product Specifications

Performance

  • SpO2 Accuracy: 70 to 100% within 3 digits (Arms)
  • Low Perfusion Accuracy: 70 to 100% within 2 digits (Arms)
  • Pulse Rate Accuracy: 40 to 240 BPM within 3 digits
  • Application Site: Ear lobe, clip style

Configuration

  • Cable Length: 1 m
  • Sensor Technology: PureLight LED ear clip, reusable
  • Compatibility: Nonin pulse oximeters per the manufacturer Sensor Compatibility Guide
  • Latex: Not made with natural rubber latex

See all Oximeter Accessories for the full range, or Shop more Nonin Products for the complete line.

Why Clinicians Keep an 8000Q2 in the Sensor Drawer

Every service eventually meets the patient whose fingers cannot host a sensor. Having a validated ear clip on hand turns that moment into a site change instead of a monitoring gap.

  • Monitoring Without Digits – the ear site covers burns, dressings, edema and poor peripheral flow.
  • Fast Spot Checks – clip on application suits rapid assessment workflows.
  • Low Perfusion Credibility – a 2 digit low perfusion declaration supports use on difficult patients.
  • No Consumables – the reusable clip needs no wraps or adhesives.

Manuals and Troubleshooting Guides

Frequently Asked Questions (FAQs)

When should the ear clip be used?

The manufacturer positions it for monitoring when digits are not the preferred site, and for fast spot checking. Common cases include poor finger perfusion, dressings and injuries.

How accurate is the ear clip sensor?

Saturation accuracy is declared within 3 digits from 70 to 100 percent, and within 2 digits under low perfusion conditions. Pulse rate accuracy is within 3 digits from 40 to 240 BPM.

Does it need wraps or adhesive?

No. The sensor clips directly onto the ear lobe, which makes application and removal quick.

What cable length does it have?

The ear clip sensor comes with a 1 meter cable. Extra reach can be added with a UNI-EXT extension cable where an installation needs it.

Which monitors does it fit?

Nonin oximeters that accept PureLight sensors, per the manufacturer Sensor Compatibility Guide. Tabletop and handheld models across the range accept the ear clip.

View AllClose

Warranty Information

This product may be covered under the manufacturer's original warranty. Please refer to the manufacturer's documentation or contact us for assistance.
View AllClose

0 Reviews

View AllClose

Explore our wide range of medical products, enjoy hassle-free shopping, and take advantage of our exclusive offers. Free shipping on orders over $50! Need assistance? Contact our friendly customer support team at (800) 494-5750. Happy shopping!