Description
Nonin PalmSAT 2500A Handheld Pulse Oximeter with Alarms, PureSAT SpO2 and 60 Hour Battery Life
The Nonin PalmSAT 2500A adds audible and visual alarms to the proven PalmSAT handheld platform. It runs about 60 hours on four AA batteries and keeps the low perfusion performance that makes the series a pediatric favorite.
- Audible and visual alarms with adjustable settings and alarm recall
- About 60 hours of operation on four AA alkaline batteries
- Low perfusion filter and smart averaging for small, moving patients
- Alarm bar, alarm silence indicator and pulse rate tone built in
PalmSAT 2500A Handheld Oximetry with Full Alarm Functions
Some handheld work needs more than a number on a screen, and this alarmed version is built for monitored spot checks and observation areas. High and medium priority alarms watch saturation and pulse rate, with adjustable limits, an alarm silence control and a recall function that restores the previous settings. The display set includes an alarm bar, a sensor fault display and a pulse quality indicator, so staff can see both the value and the state of the measurement. Under the alarms sits the same PureSAT engine as the standard model, with low perfusion filtering that performs on neonates and infants. Smart Averaging settles readings quickly, and true pulse detection resists the motion artifact that active toddlers produce. Sixteen PureLight sensor configurations let each service match the handheld to its patient mix.
Features and Benefits
Alarm System
- High and Medium Priority Alarms – audible and visual alerts for saturation and pulse rate events.
- Alarm Recall – previous alarm settings can be reviewed and recalled between patients.
- Alarm Silence Indicator – the display shows when audible alarms are silenced, with a dedicated alarm bar.
Measurement Platform
- Low Perfusion Filter – extracts dependable readings from weak signals on small patients.
- Smart Averaging – automatic averaging that can settle in about three seconds.
- Pulse Rate Tone – an audible tone tracks each detected pulse.
Product Specifications
Performance
- Oxygen Saturation Range: 0 to 100% SpO2
- Pulse Rate Range: 18 to 321 beats per minute
- Displays: 3-digit, 7-segment LED with alarm bar and pulse quality indicator
- Ingress Protection: IP32, Type BF applied part
Power, Size and Warranty
- Battery: Four 1.5V AA alkaline batteries, about 60 hours, or NiMH rechargeable pack
- Dimensions: 5.4 in H x 2.8 in W x 1.3 in D (13.8 x 7.0 x 3.2 cm)
- Weight: 7.4 oz (210 g) with alkaline batteries
- Warranty: 3-year manufacturer warranty
See all Handheld Pulse Oximeters for the full range, or Shop more Nonin Products for the complete line.
Why Monitored Areas Choose the PalmSAT 2500A
Observation bays and step down areas need handheld convenience with monitor grade alerting. This version bridges that gap, alarming like a monitor while staying light enough to carry room to room.
- Alarms Without a Bedside Monitor – priority alarms and a silence indicator support supervised observation anywhere.
- Settings That Persist – alarm recall restores configured limits, reducing setup variation between staff.
- Small Patient Accuracy – the low perfusion platform keeps neonate and infant readings dependable.
- Shared Sensor Stock – PureLight sensors are shared with the standard PalmSAT and other Nonin monitors.
Manuals and Troubleshooting Guides
Frequently Asked Questions (FAQs)
What alarms does the PalmSAT 2500A provide?
It provides high and medium priority audible and visual alarms for saturation and pulse rate. Alarm limits are adjustable, and an alarm silence indicator and alarm bar are built into the display.
How long do the batteries last?
Four AA alkaline batteries provide about 60 hours of typical operation. A NiMH rechargeable battery pack and charger stand are available as accessories.
Can previous alarm settings be recalled?
Yes. The alarm functions include reviewing and recalling previous alarm settings, which keeps configurations consistent between patients.
Is the 2500A good for infants?
Yes. It uses the same low perfusion filtering and PureLight sensor range as the standard model, including neonatal and infant flex sensors.
What warranty covers the PalmSAT 2500A?
The manufacturer provides a 3-year warranty on the handheld. The operator manual states the complete terms.