Description
The Fisher & Paykel Optiflow Junior 2 Nasal Cannula delivers nasal high flow therapy to infants and children in six sizes, from extra small to XXL. Its Waveflex technology and Wigglepads 2 fitting system are designed to keep the cannula placed on small, active patients.
- Six sizes – XS through XXL cover the infant and pediatric range, in packs of 20 (XXL packs of 10).
- Waveflex technology – the cannula flexes with the patient to help maintain placement.
- Wigglepads 2 fitting – hydrocolloid pads secure the cannula to the cheeks, per the manufacturer's specification sheet.
- Documented flow ranges – with MR850 and RT330, flows run from 1.1 L/min up to 36 L/min on the XXL, per the spec sheet.
& Paykel Optiflow Junior 2 Nasal Cannula with six sizes
The Optiflow Junior 2 is Fisher & Paykel's nasal cannula for infant and pediatric nasal high flow therapy. The manufacturer's specification sheet documents the system in detail: six sizes, per-size cannula weights from 6.7 to 28.2 grams, flow ranges for use with the MR850 humidifier and RT330 circuit, a 14-day duration of use, and single-patient use. The cannula is not made with natural rubber latex, PVC or phthalates (DEHP, DBP, BBP). Wigglepads 2 hydrocolloid pads hold it to the cheeks. For neonatal and pediatric units, this is the specified interface for F&P infant high flow.
Features and Benefits
Pediatric Design
- Flex placement support – flexes with the patient to support cannula placement.
- Six-size range – XS, S, M, L, XL and XXL sizes with per-size weights from 6.7 g to 28.2 g.
- Materials – not made with natural rubber latex, PVC or phthalates, per the spec sheet.
Fitting System
- Wigglepads 2 – hydrocolloid pads secure the cannula on the cheeks.
- Documented flows – size-specific flow ranges with MR850 and RT330 are published in the specification sheet.
- Use limits – 14-day duration of use, single patient use, per the manufacturer.
Product Specifications
- Interface Type: Infant and pediatric nasal cannula for nasal high flow therapy
- Sizes and Weights: XS 6.7 g, S 7.1 g, M 9.3 g, L 13.5 g, XL 13.8 g, XXL 28.2 g
- Flow Range (MR850 + RT330): XS 1.1 to 8, S 1.1 to 9, M 1.1 to 10, L 1.1 to 23, XL 1.1 to 25, XXL 1.1 to 36 L/min
- Supply: Pack of 20 (XXL pack of 10); L and XL also offered in packs of 5
- Duration of Use: 14 days, single patient use
- Materials: TPE, hydrocolloid, ABS, stainless steel; not made with latex, PVC or phthalates
- Configurations: Size: XS, S, M, L, XL, XXL, L (Pack of 5), XL (Pack of 5)
Browse the full Hospital Supplies range, or shop everything from Fisher & Paykel.
Why Choose the Optiflow Junior 2 Nasal Cannula?
Infant high flow succeeds or fails on cannula placement, and placement is a fitting problem. The Junior 2 system, Waveflex cannula plus Wigglepads 2 plus a six-size range, is engineered as one answer to that problem.
- Complete size ladder – six sizes from the smallest infants upward.
- Placement system – Waveflex and Wigglepads 2 work together to keep prongs placed.
- Published specifications – flows, weights and use limits are documented by the manufacturer.
- The differentiator – the only infant cannula in this catalog with a dedicated hydrocolloid fitting system.
Manuals and Troubleshooting Guides
Frequently Asked Questions
What sizes does the Optiflow Junior 2 come in?
The Optiflow Junior 2 comes in six sizes: XS, S, M, L, XL and XXL. This listing offers all six, with L and XL also available in packs of 5.
What flow can each size deliver?
Each size delivers a documented flow range with the MR850 and RT330: XS 1.1 to 8, S 1.1 to 9, M 1.1 to 10, L 1.1 to 23, XL 1.1 to 25 and XXL 1.1 to 36 L/min.
How long can one cannula be used?
One cannula can be used for up to 14 days; the manufacturer specifies a 14-day duration of use, single patient use.
How is the cannula held in place?
The cannula is held in place with Wigglepads 2 hydrocolloid pads on the cheeks, part of the Junior 2 fitting system.
Does it contain latex or PVC?
No. The manufacturer states it is not made with natural rubber latex, PVC or phthalates.