Description
The PageWriter TC Complete Lead Set is a genuine Philips ECG lead set made for Philips PageWriter TC Series cardiographs (models 860310 and 860315). With alligator clip electrode attachment, AAMI color coding, it gives clinicians a dependable connection for everyday ECG work. Philips builds this accessory for its own equipment, which keeps fit and performance aligned with the host device.
- Electrode Attachment: Alligator Clip
- Color Coding: AAMI
- Product Type: Diagnostic ECG patient cables and leads
- Compatibility: PageWriter TC Series cardiographs
A Complete Lead Set for PageWriter TC Cardiographs
Clean tracings start at the skin, with a lead set that connects securely and codes every position clearly. It is made for Philips PageWriter TC Series cardiographs (models 860310 and 860315), with AAMI color coding that reduces placement errors during busy study schedules. The alligator clip terminations grip standard ECG electrodes securely, which keeps the trace stable while the patient moves or is repositioned during limb, chest recordings.
The set serves adult and pediatric patients at the limb, chest, with shielding that limits interference from nearby equipment. Its multi-patient use rating means one set covers many studies, cleaned between patients as the Philips instructions for use direct. Philips manufactures it without natural rubber latex.
Features and Benefits
Design and Performance
- Color Coding: AAMI color coding helps staff place every lead correctly on the first attempt
- Shielding: Shielded construction limits electrical interference for a cleaner ECG trace
- Electrode Attachment: Alligator Clip terminations connect securely to standard ECG electrodes
- Patient Application: Rated for child, adult patients in routine and critical care areas
- Use Design: Multi-patient use spreads the cost of one set across many studies
- Natural Rubber Latex: Not manufactured with natural rubber latex
Product Specifications
Product Details
- Product Category: ECG
- Product Type: Diagnostic ECG Patient Cables and Leads
- Patient Application: Child, Adult
- Application Site: Limb, Chest
- Color Coding: AAMI
- Electrode Attachment: Alligator Clip
- Use Design: Multi-Patient Use
- Sterility: Non-Sterile
- Natural Rubber Latex: Not manufactured with natural rubber latex
- CE Certified: No
- Use with Non-Philips Equipment: No, Philips equipment only
Physical Specifications
- Shielding: Shielded construction
- Package Weight: 250 g
- Packaging: 1
Compatibility
- Compatible Philips Equipment: 860315, 860310
Keep the whole care area stocked from our Hospital Supplies range. The rest of the Philips catalog we offer sits on the Philips Healthcare brand page.
Why Choose This Product
There is a practical reason the specified part outsells the substitutes: it works the first time, on the equipment Philips lists for it. That reliability is the entire value of the OEM accessory.
- Genuine Philips OEM: Philips own accessory, made by the manufacturer of the host device
- Published Compatibility: Philips specifies this part for Philips PageWriter TC Series cardiographs (models 860310 and 860315)
- Exact Fit: Fit follows the host equipment specification without adaptation
- Latex Consideration: Not manufactured with natural rubber latex for latex sensitive areas
- Cost Over Time: Multi-patient use spreads one purchase across many patients and studies
Frequently Asked Questions
What Philips equipment is this accessory made for?
Philips designates it to Philips PageWriter TC Series cardiographs (models 860310 and 860315). Every covered model is listed in the specifications above, and the accessory is made for Philips equipment only.
Are the terminations compatible with standard ECG electrodes?
Yes, the alligator clip terminations connect to standard ECG electrodes for limb, chest recordings in routine and diagnostic work. Check that your electrode style matches the termination when you restock.
Which trunk cables pair with this lead set?
Philips publishes the matching trunk cables in the specifications above. From the lead set, the trunk cable carries the signal onward to the monitor or cardiograph.
Is it rated for multi-patient use?
Yes, it is rated for multi-patient use. With cleaning between patients per the Philips instructions for use, it stays in service study after study.
Is natural rubber latex used in its construction?
No, Philips manufactures it without natural rubber latex. That suits care areas that manage latex sensitivity.
Am I ordering the genuine Philips part?
Yes, it is the genuine Philips accessory made for the listed equipment. Original Philips parts follow the same design standard as the host device.