Description
The Schiller ISA Sidestream Analyzer is a sidestream gas analyzer platform offered in CO2-only and multi-gas configurations with anesthetic agent identification. It is made for operating rooms and critical care areas that monitor respiratory gases and anesthetic agents.
- Draws the gas sample to the analyzer
- The full configuration measures CO2
- The 601 configuration measures CO2
- Supplies the gas monitoring behind the ISA configurations of Schiller patient monitors
Schiller ISA Sidestream Analyzer in Detail
Draws the gas sample to the analyzer, which keeps the sensor away from the airway. The ISA design is made by Masimo and supplied through Schiller for its monitoring platforms. Agent identification removes the need to tell the monitor which agent is in use. A fixation accessory is needed to mount the analyzer and should be ordered for the installation, check the current listing details before ordering. Sidestream analyzers pair with Nomoline sampling lines and adapters to carry the sample from the airway. That is the combination operating rooms and critical care areas that monitor respiratory gases and anesthetic agents rely on day after day.
Features and Benefits
- Sidestream Sampling – draws the gas sample to the analyzer, which keeps the sensor away from the airway
- Multi-Gas Configurations – the full configuration measures CO2, O2, N2O and five anesthetic agents with automatic agent identification
- Mid Configuration – the 601 configuration measures CO2, N2O and five anesthetic agents with agent identification, without the O2 channel
- Monitor Integration – supplies the gas monitoring behind the ISA configurations of Schiller patient monitors
Product Specifications
Key Specifications
- Type – Sidestream gas analyzer
- Configurations – CO2 only, CO2, N2O, 5 agents with ID, CO2, O2, N2O, 5 agents with ID
- Agent Identification – Automatic on multi-gas configurations
Packaging
- Sold As – CO2 Only: Each, CO2, N2O, 5 Agents with Agent ID: Each, CO2, O2, N2O, 5 Agents with Agent ID: Each
See the full Schiller range at MedicalEx, and browse ECG machines and diagnostic equipment in the diagnostic catalog.
Why Choose This Gas Analyzer
Choosing the manufacturer's own gas analyzer removes the guesswork that comes with substitutes. For operating rooms and critical care areas that monitor respiratory gases and anesthetic agents, the fit, the function and the part number are the ones the system documentation assumes.
- Genuine Schiller supply – supplied through Schiller Americas as the manufacturer item, not a third-party substitute
- Fits the workflow – it is made for operating rooms and critical care areas that monitor respiratory gases and anesthetic agents
- Packaging as listed – sold as co2 only: each, co2, n2o, 5 agents with agent id: each, co2, o2, n2o, 5 agents with agent id: each, with the price shown for that package
- Part of the Schiller line – matching Schiller cables, consumables and accessories are listed in the same catalog
Frequently Asked Questions
What is the difference between the 401 and 601 configurations?
The 401 configuration measures CO2, O2, N2O and five anesthetic agents with identification, while the 601 configuration measures CO2, N2O and five anesthetic agents with identification and omits the O2 channel.
Is there a CO2-only version?
Yes, the base configuration measures CO2 only.
Does the analyzer identify the anesthetic agent automatically?
Yes, the multi-gas configurations identify the agent automatically.
What sampling lines does it use?
It pairs with Nomoline sampling lines and adapters.
Who makes the ISA analyzer?
The ISA sidestream design is made by Masimo and supplied through Schiller for Schiller monitoring platforms.