Description
The Invotec Shea Parasol Vent Tube opens like its namesake inside the middle ear, a silicone parasol that folds to enter the myringotomy and blooms to retain the tube. A tab keeps removal simple, and the 1.02 mm lumen ventilates while the parasol holds.
- Parasol Retention – The umbrella profile folds for entry and opens behind the membrane, so retention comes from shape, not stiffness.
- Removal Tab – A built-in tab gives the clinician something to grasp, so removal at term is a single motion.
- Soft Silicone – The parasol flexes with the membrane, so long contact stays gentle.
The Tube That Blooms in Place
Shea's parasol is one of otology's elegant ideas: a tube that travels folded and deploys open. The silicone parasol passes through the myringotomy in its slim state, then opens on the middle ear side like an umbrella, anchoring the tube without rigid flanges. The 1.02 mm lumen runs through its stem, ventilating and draining for the tube's whole term.
When the term ends, the tab answers the removal question: grasp it and the parasol folds back out the way it came. Sterile and boxed by ten, it is the design surgeons reach for when they want retention with a planned, graceful exit.
Features and Benefits
- Parasol Design: Folds for placement, opens for retention
- Removal Tab: Built-in tab for controlled removal
- Silicone: Soft medical grade material
- 1.02 mm Inner Diameter: Ventilation lumen
- Sterile: Supplied sterile, ten per box
Product Specifications
Product Details
- Product Type: Ventilation tube, Shea parasol
- Material: Silicone, medical grade
- Inner Diameter: 1.02 mm
- Removal: Integrated tab
- Sterility: Sterile
Packaging
- Quantity Per Box: 10 tubes
Warranty and Support
- Manufacturer Warranty: Covered against defects in material and workmanship, with replacement or refund for defective merchandise under the manufacturer's Returned Goods Policy
Browse the full Surgical Instruments range, or shop everything from Invotec International.
Why a Parasol
Retention and removability usually fight each other. The parasol settles the argument with geometry: open to stay, folded to leave, and a tab to make the leaving deliberate.
- Shape-Based Retention – The opened parasol anchors without rigid flanges.
- Planned Exit – The tab makes removal a controlled, single motion.
- Gentle Material – Silicone flexes against the membrane for the whole term.
Manuals and Troubleshooting Guides
Invotec Shea Parasol Vent Tube – Ventilation Tubes Instructions for Use
Frequently Asked Questions
How does the parasol tube stay in place?
The silicone parasol folds to pass through the incision, then opens on the middle ear side like an umbrella, anchoring the tube.
What is the tab for?
The tab gives the clinician a grasping point so the tube can be removed deliberately at the end of its term.
What is the lumen size?
The inner diameter is 1.02 mm, sized to the parasol’s fine silicone stem.
What material is it?
Soft medical grade silicone, flexible enough to fold for placement and open in place.
Is it sterile?
Yes. The parasol tubes are sterile, ten per box.
What warranty applies?
Invotec warrants its merchandise against defects in material and workmanship, with replacement or refund for defective items under its Returned Goods Policy.