Description
The Medtronic Sonicision cordless ultrasonic dissection system is available from MedicalEx in the configurations listed below. These are the reusable power components of the cordless ultrasonic system: the reusable generator, the battery charger and the battery insertion guide that keep Sonicision dissectors running.
- Reusable generator for the Sonicision 2 dissector
- Battery charger with easy charge status checks
- Battery insertion guide, two per pack
- Cordless system: no generator cart or cords in the field
Browse the full Electrosurgery range, or shop everything from Medtronic.
Main Description
The Sonicision system is Medtronic's cordless ultrasonic dissection platform, in which a battery-powered handpiece coagulates and dissects vessels without a cord to a cart-based generator. The configurations listed here are the system's reusable power components: the reusable generator that drives the dissector, the battery charger, and the reusable battery insertion guide. The current Sonicision 7 curved jaw device coagulates and dissects vessels up to and including 7 mm. The original platform was rated to 5 mm. A cordless format removes cord management from the sterile field and lets the instrument move between rooms without a dedicated generator. The reusable components are processed and maintained per their instructions for use. The charger reports charge status for the battery packs.
Features and Benefits
- Cordless architecture – Battery power in the handpiece is the system's defining trait, clearing cords from the field.
- Reusable generator – The generator component is rated for repeated procedural use, spreading its cost across many cases.
- Charge visibility – The charger makes battery status easy to check, so cases do not start on a flat pack.
- Guided battery handling – The insertion guide standardizes battery changes between cases.
Product Specifications
Product Facts
| System | Cordless ultrasonic dissection platform |
| Components Listed | Reusable generator, battery charger, battery insertion guide |
| Dissector Rating | Sonicision 7 seals/dissects vessels up to and including 7 mm (original platform 5 mm) |
Packaging and Configurations
| Use | Reusable components, processed per IFU |
| Package | Per configuration as listed |
Product Line
| Brand | Medtronic |
| Product Family | Sonicision cordless ultrasonic dissection system |
Distribution
| Availability | Continental US |
| Package Quantity | pk (per configuration as listed) |
Why Choose This Product
Facilities running Sonicision dissectors need genuine generators and chargers to keep the fleet alive. These are those components, listed plainly. Cordless dissection is chosen for field freedom, and that choice depends on charged batteries and working generators every day.
- Fleet uptime – Spare generators and chargers are the differentiator between a cordless program that runs and one that stalls.
- No cart dependency – The system needs no cart generator, so rooms without energy capital can still run ultrasonic dissection.
- Status at a glance – Charger charge indication prevents the flat-battery case delay.
Frequently Asked Questions
Do these configurations include the dissector handpiece?
No. The listed configurations are the reusable generator, the battery charger and the battery insertion guide for the Sonicision 2 dissector system. The dissectors themselves are separate products.
How many uses does the reusable generator support?
The Sonicision platform's reusable generator and battery system is designed for repeated use across many procedures, roughly double the previous generation per Medtronic's distributor materials. The IFU governs inspection and retirement criteria.
Is this device sterile and single use?
Yes. It is supplied sterile for single use unless its label states otherwise, and it must not be reprocessed or reused. Check the package integrity and expiry before every case.
How should this device be stored?
Store it in its original packaging under normal room conditions away from heat sources and moisture. Rotate stock by expiry date and quarantine any unit with damaged packaging.
What if a configuration I need is not listed?