Description
Sultan PeelPro Sterilization Pouches give cost-conscious practices a value priced pouch that still tracks the cycle inside and out. Dual internal and external steam and gas indicators meet CDC guidelines for an internal indicator in every pack. A double wide seal guards against punctures from instrument tips, so value pricing never comes at the cost of pack integrity.
- Dual Indicators Inside and Out – Internal and external steam and gas indicators meet CDC guidelines, so every pack carries proof of processing.
- Double Wide Seal – The extra seal width adds puncture protection where instrument tips press against the pouch, which keeps packs intact in storage.
- Wet-Strength Paper – Medical grade paper allows steam to penetrate and remains strong when wet, so pouches hold together through the full cycle.
- Five-Year Sterility Window – Certified for a minimum five year post-sterilization life, so processed inventory stays ready far longer.
Value Priced Self-Seal Pouches with Full Indicator Coverage
Value pouches often cut corners on monitoring, and that trade shows up during an audit. This line keeps the monitoring complete: an internal indicator rides in every pack per CDC guidelines, and external indicators mark the pack as processed. The film side stacks multiple layers, including a heat-resistant polyester outer layer and polypropylene layers built for tear strength, over a tough porous medical grade paper. A double wide seal answers the most common pouch failure, the puncture, with extra material where sharp tips land. For high-volume practices watching consumable costs, Sultan PeelPro Sterilization Pouches hold the sterilization protocol together without the premium price.
Features and Benefits
Indicator Coverage
- Internal Indicator in Every Pack – A dual internal indicator meets CDC guidelines for the use of an internal indicator, so monitoring never depends on a separate strip.
- External Process Indicators – Steam and gas indicators on the outside confirm the pack went through the sterilizer before it reaches the operatory.
Film and Seal Construction
- Double Wide Seal – The widened seal zone delivers excellent puncture protection against hinges, tips and cassette corners.
- Multi-Layer Aqua Film – The see-through aqua tint film layers polyester and polypropylene over medical grade paper, combining visibility with tear strength.
- Porous Medical Grade Paper – The paper layer allows air evacuation and steam or gas penetration, and it remains strong when wet during the cycle.
Handling
- Self-Seal Closure – The adhesive strip closes each pouch by hand, so no heat sealer investment or warm-up time is needed.
Product Specifications
Pouch Details
- Pouch Type: Self-seal sterilization pouch
- Indicators: Dual internal and external steam and gas indicators
- Seal: Double wide seal
- Film: Multi-layer, aqua tint, see-through
- Post-Sterilization Life: Certified minimum 5 years
- Sterilization Methods: Steam and gas
Sizes and Packaging
- Size Range: 2-3/4 x 10 in up to 7-1/2 x 13 in, 5 sizes
- Quantity Per Box: 200 pouches per box, all sizes
Explore More: See all Dental Supplies | Shop more Sultan Products
Why Budget-Minded Practices Pick This Pouch Line
Sterilization consumables run through a practice by the thousands, so unit price matters on every pack. This line keeps the safety elements that auditors check, including the internal indicator and a puncture-resistant seal, while trimming the price. One five-size range also simplifies ordering for the front desk.
- Value Price, Full Protocol – CDC-aligned internal monitoring at a value price is the differentiator, because cheap pouches usually drop the internal indicator first.
- Fewer Puncture Failures – The double wide seal cuts down on repacks caused by tip punctures, which saves staff time across hundreds of cycles.
- Five-Year Certified Life – Processed packs stay certified far longer, so the practice reprocesses less and wastes fewer pouches.
- Simple Five-Size Range – Five sizes cover hand instruments through kits, which keeps ordering and stocking straightforward for the whole team.
Frequently Asked Questions
Do these pouches include an internal indicator?
Yes, dual internal and external steam and gas indicators are built into every pouch. That meets CDC guidelines for the use of an internal indicator without buying separate strips.
What makes the seal puncture resistant?
The seal is double wide, so instrument tips and cassette corners press against a broader bonded zone. The multi-layer film adds tear strength on top of that wider seal.
How long do sealed packs stay sterile?
The pouches are certified for a minimum post-sterilization life of five years. Staff should still check each pack for seal damage or moisture before use.
Which sterilization methods can be used?
The medical grade paper allows steam and gas penetration, so the pouches suit steam autoclaves and gas sterilizers. The indicators respond to both processes.
How many pouches are in a box?
Every size in this line packs 200 pouches per box. Five sizes run from 2-3/4 x 10 in up to 7-1/2 x 13 in.
Is a heat sealer needed to close them?
No, each pouch closes with its own self-seal adhesive strip. That keeps the packaging station simple and fast.