Description
Sultan Sporox II Sterilizing and Disinfecting Solution gives heat sensitive instruments a sterilant that skips the glutaraldehyde drawbacks entirely. The hydrogen peroxide formula arrives ready to use, with no mixing, heating or activation standing between the tray and the first load. Sterilization lands in six hours and high level disinfection in thirty minutes, so the liquid sterilization workflow fits a real clinical day.
- Ready to Use – No mixing, heating or activation is required, so the solution goes from the shelf straight into the soaking tray.
- Six Hour Sterilization – Full sterilization is achieved in six hours, with high level disinfection in thirty minutes for faster turns.
- 21 Day Reuse – One fill keeps working for up to 21 days, which stretches each gallon across weeks of instrument loads.
- No Noxious Odors – The peroxide formula avoids the irritating fumes tied to glutaraldehydes, keeping the sterilization area easier on staff.
Hydrogen Peroxide Sterilant for Heat Sensitive Instruments
Liquid sterilization exists for the instruments that cannot take autoclave heat, and the chemistry choice shapes the whole work area. This solution uses hydrogen peroxide to oxidize dental debris and contaminants quickly and effectively, instead of bonding infectious proteins to instruments the way glutaraldehydes can. It provides effective infection control without irritating glutaraldehydes, and staff notice the difference in the air around the tray. The same fill sterilizes in six hours or disinfects at a high level in thirty minutes, then keeps working for up to 21 days of reuse. Paired with a soaking tray, Sultan Sporox II Sterilizing and Disinfecting Solution gives the practice a complete cold sterilization station without an activation ritual.
Features and Benefits
Chemistry and Safety
- Hydrogen Peroxide Based – The oxidizing formula attacks debris and contaminants directly and leaves no protein bonding behind on instruments.
- Glutaraldehyde Free Approach – The solution avoids the skin, eye and airway irritation OSHA associates with glutaraldehyde exposure.
- No Noxious Odors – A low odor profile keeps the reprocessing area comfortable during long soaks.
Workflow
- No Activation Steps – Ready to use pours straight into the tray, so setup takes seconds and never waits on heating or mixing.
- Two Processing Levels – Six hours achieves sterilization and thirty minutes achieves high level disinfection, covering both turnaround needs.
- Extended Reuse Window – The solution can be reused for up to 21 days, with activity verified by the matching test vials.
Product Specifications
Solution Details
- Active Chemistry: Hydrogen peroxide based sterilant and high level disinfectant
- Container: 1 gallon (3.8 L) bottle
- Preparation: Ready to use, no mixing, heating or activation
Processing Times
- Sterilization Time: 6 hours immersion
- High Level Disinfection Time: 30 minutes immersion
- Reuse Life: Up to 21 days
- Intended Instruments: Heat sensitive instruments that cannot be autoclaved
Explore More: See all Dental Supplies | Shop more Sultan Products
Why Practices Move Off Glutaraldehyde
The sterilant tray sits in a staffed room all day, so its fumes and handling rules shape the work environment. A peroxide solution that needs no activation removes both the odor problem and the prep steps. The 21 day reuse window then keeps the cost per load low across the month.
- Kinder Work Area – No noxious odors and no glutaraldehyde irritation is the differentiator staff feel on day one.
- Zero Prep Ritual – Ready to use means the first load starts immediately, which keeps heat sensitive instruments cycling on schedule.
- Weeks per Fill – Up to 21 days of reuse stretches one gallon across many loads, lowering the cost of every cycle.
- Two Speeds in One Tray – Sterilization in six hours or high level disinfection in thirty minutes lets the team match the process to the clock.
Frequently Asked Questions
How long does sterilization take?
Sterilization is achieved in six hours of immersion. High level disinfection takes thirty minutes when a faster turnaround is enough.
Does the solution need activation or mixing?
No, it is ready to use with no mixing, heating or activation required. Pour it into the soaking tray and start the first load.
How many times can one fill be used?
The solution can be reused for up to 21 days. Sporox test vials check hydrogen peroxide activity to confirm when a change is due.
Why choose peroxide over glutaraldehyde?
The peroxide formula avoids the irritating fumes and sensitization risk tied to glutaraldehydes. It also oxidizes debris instead of bonding infectious proteins to instrument surfaces.
What size container does it come in?
It ships as a single one gallon bottle, ready to pour. One gallon fills the one gallon ProSoak tray exactly.
Which instruments is it for?
It serves heat sensitive instruments that cannot be autoclaved. Immerse cleaned instruments as directed on the product label for the chosen processing level.