Description
The V. Mueller Genesis Sterilization Container – 19 x 12 x 4 Inch – Solid Bottom is the mid-length rigid container in the Genesis system, sized between the half-length and full-length models to enclose a mid-size instrument set through sterilization and to keep that set sterile until the moment it is opened. The solid bottom works with the perforated Genesis lid and its single-use filter, so sterilant circulates through the lid during the cycle while the load rests on a smooth, unperforated base. STERIS validates the Genesis system to maintain sterility for up to 180 days, which lets a sterile processing department build sets ahead of the surgical schedule instead of against it.
- Mid-length 19 x 12 inch footprint for mid-size instrument sets
- Solid bottom and filtered lid pass sterilant through the lid
- Hard-coated anodized aluminum that stacks and resists corrosion
A Mid-Length Rigid Container Built Around the Filtered Lid
The Genesis design puts the microbial barrier in the lid. Two filter retention plates on the underside of the lid hold a single-use Genesis filter sheet over the lid perforations, and that filter passes steam or ethylene oxide during the cycle, then blocks microbes for the whole storage period. This model pairs that lid with a solid base, so sterilant reaches the load through the lid alone while the base stays a smooth tray with no perforations to trap debris. A data card slot on the end panel records the load, and tamper-evident arrows lock the lid to show at a glance that the set has not been opened. Large handles sit close to the body for a controlled lift, and the hard-coated anodized aluminum shell resists the scratches and corrosion that end the life of lesser containers.
Features and Benefits
- Solid Bottom Design: Unperforated base gives the load a smooth floor while sterilant circulates through the filtered lid
- Filtered Lid Barrier: Lid perforations and a single-use filter pass sterilant, then hold the microbial barrier
- 180-Day Sterility Maintenance: Validated storage window lets departments build sets well ahead of the schedule
- Hard-Coated Anodized Aluminum: Shell resists corrosion, scratches and everyday wear in the decontamination area
- Stackable Footprint: Mid-length containers stack to save shelf and cart space in sterile storage
- Data Card and Tamper Arrows: End-panel card records the load while arrows show the set has stayed sealed
Product Specifications
Product Details
- Brand: V. Mueller
- Manufacturer: STERIS Corporation
- Model Number: CD2-4C
- Catalog Number: CD24C
- Product Type: Reusable rigid sterilization container
- Sold As: Each
Dimensions and Construction
- Nominal Size: 19 x 12 inches, 4 inches deep
- Metric Size: 48.3 x 30.5 cm, 10.2 cm deep
- Bottom Style: Solid
- Material: Hard-coated anodized aluminum
Sterilization and Compliance
- Compatible Modalities: Pre-vacuum steam, immediate-use steam and 100% ethylene oxide
- Steam Cycle: 270°F (132°C) for 4 minutes with a 30 minute dry time
- Sterility Maintenance: Up to 180 days when used as directed
- FDA Product Code: KCT, sterilization wrap containers, trays, cassettes and accessories
- Regulation: 21 CFR 880.6850, Class II
Browse the full Instrument Trays and Sterilization range, or see every V. Mueller product we carry.
Why Choose the Genesis Mid-Length Container
A rigid container earns its place when it removes work from every cycle after the first one, and the mid-length footprint sizes that benefit to the sets that outgrow a half-length container without needing a full-length one. The Genesis system replaces wrap with a reusable shell, a fresh filter and a documented load, so the same set travels from decontamination to storage to the operating room in one closed unit.
- Mid-length size takes mid-size sets without wasted container volume
- Solid base gives the load a smooth, unperforated floor
- Reusable shell cuts the ongoing cost and waste of sterilization wrap
- Works with the Genesis mid-length baskets, dividers and instrument holders sized to this footprint
Frequently Asked Questions
Which sterilization cycles can this container run?
The Genesis system is validated for pre-vacuum steam at 270°F (132°C) for 4 minutes with a 30 minute dry time, for immediate-use pre-vacuum steam, and for 100% ethylene oxide. Because sterilizers vary, STERIS directs each facility to verify the cycle parameters for its own sterilizer before use.
How long does the container keep a set sterile?
Used as directed with Genesis filters, tamper-evident arrows and data cards, the system maintains sterility of the enclosed devices for up to 180 days. The arrows show at a glance whether the sealed set has been opened in the meantime.
What goes inside the lid?
A single-use Genesis filter sheet sits over the lid perforations, held by two filter retention plates on the underside of the lid. Filters, arrows and data cards are single-use parts and are replaced with every cycle.
How is this container different from the perforated bottom Genesis containers?
This model has a solid bottom, so sterilant circulates through the filtered lid only. The perforated bottom Genesis containers, such as the half-length CD14B, also pass sterilant up through the base of the container while the load processes.
What is the container made of?
The shell is hard-coated anodized aluminum, the finish STERIS specifies to protect the container from corrosion, scratches and wear. The containers stack for storage and carry large handles that keep the load close to the body when lifted.
Does it need a basket inside?
A basket is not required for the container to seal or sterilize, but Genesis baskets and dividers organize instruments inside the container and protect them in transit. Mid-length Genesis baskets are sized to this footprint.