Description

The V. Mueller Genesis Tamper-Evident Arrows – Steam – White Double-Barbed – Box of 500 are the single-use seals that close a Genesis container and prove it stayed closed. Each white double-barbed arrow seats through the latch of a Genesis container before the load runs, and the printed tab darkens in the autoclave so a processed set announces itself at a glance. If the arrow is broken or missing when the set reaches the field, the team knows the container was entered and treats the contents accordingly.

  • Double-barbed shaft locks into the container latch
  • Printed indicator tab darkens when autoclaved
  • Box of 500 single-use arrows for Genesis containers

A Steam Seal Made for the Genesis Container System

A Genesis container closes with a filtered lid, and the lid stays honest because of a small plastic arrow. The arrow slides through the aligned latch points of lid and base, and the two barbs behind its tip flex on the way in and spring back against removal, so the seal cannot be slipped off and replaced unnoticed. The wide tab gives staff a firm grip for seating the arrow and a clear read at the other end of the cycle, because the printed legend darkens only after steam exposure. When a set comes out of storage, one look settles two questions, since the darkened tab says the load was processed and the intact arrow says nobody opened the container since. Arrows are replaced with every cycle, right alongside the filter sheet and the data card, so each run starts with a fresh seal.

Features and Benefits

  • Double-Barbed Shaft: Two barbs lock the arrow into the latch so the seal resists removal
  • Steam Indicator Tab: Printed legend darkens when autoclaved, showing the load was processed
  • Tamper Evidence at a Glance: A broken or missing arrow shows that the sealed set has been opened
  • White High-Visibility Tab: Wide white tab reads clearly on the container end for a fast seal check
  • Single-Use Design: A fresh arrow every cycle, replaced with the filter sheet and data card
  • Box of 500: Bulk pack sized for sterile processing departments running daily container loads

Product Specifications

Product Details

  • Brand: V. Mueller
  • Manufacturer: STERIS Corporation
  • Model Number: AS2-2
  • Catalog Number: AS22
  • Product Type: Tamper-evident container arrow
  • Sold As: Box of 500

Design and Use

  • Barb Style: Double-barbed
  • Color: White
  • Material: Plastic
  • Sterilization Modality: Steam
  • Indicator: Printed tab darkens when autoclaved
  • Container System: Genesis reusable rigid containers
  • Use: Single use, replaced every cycle

Sterilization and Compliance

  • FDA Product Code: KCT, sterilization wrap containers, trays, cassettes and accessories
  • Regulation: 21 CFR 880.6850, Class II

Browse the full Instrument Trays and Sterilization range, or see every V. Mueller product we carry.

Why Choose Genesis Tamper-Evident Arrows

A rigid container system only protects a set if the seal can be trusted, and that trust has to be visible. Genesis arrows make the seal, the processing check and the tamper check a single one-second glance, with no separate labels or loose indicators to stock.

  • One part seals the container and confirms the steam cycle
  • A fresh seal every cycle removes any doubt about a reused closure
  • Box of 500 keeps pace with daily container volume in the department
  • Made for Genesis lids and latches, so seating is consistent across the fleet

Frequently Asked Questions

What do these arrows seal?

They seal Genesis reusable rigid sterilization containers. The arrow seats through the latch points where the lid meets the base, locking the closed container before it goes into the sterilizer.

How does the indicator tab work?

The tab is printed with a steam indicator legend that darkens when the arrow is autoclaved. A darkened tab tells staff the load went through the steam cycle, while the unbroken arrow itself is the tamper evidence that the set stayed closed afterward.

Are the arrows reusable?

No. The arrows are single use and are replaced with every cycle, along with the Genesis filter sheet and data card. A fresh arrow is what makes the tamper evidence meaningful, because a reused seal could not prove the set stayed closed.

What is the difference between the white and yellow Genesis arrows?

Color marks the sterilization modality. The white AS2-2 arrow is the steam arrow with the autoclave indicator tab, while the yellow AG2-2 arrow is the gas (EO) version. Match the arrow color to the cycle the container will run.

How many arrows come in a box?

Each box holds 500 arrows. The same steam arrow is also packed 1,000 to a box under catalog number AS2-3 for departments that prefer the larger pack.

Will these arrows fit other container brands?

The arrows are sized for Genesis container latch points. Other container systems use their own seals and closures, so Genesis arrows are not a substitute for another maker's seal.

View AllClose

Warranty Information

This product may be covered under the manufacturer's original warranty. Please refer to the manufacturer's documentation or contact us for assistance.
View AllClose

0 Reviews

View AllClose

Explore our wide range of medical products, enjoy hassle-free shopping, and take advantage of our exclusive offers. Free shipping on orders over $50! Need assistance? Contact our friendly customer support team at (800) 494-5750. Happy shopping!