Description
The Medtronic Valleylab stainless steel electrode is available from MedicalEx in the configurations listed below. The classic uncoated range: blade, needle and 5 mm ball electrodes in standard and 6.5 inch extension lengths for hex-locking and standard pencils, 50 to 150 per case.
- Blade, needle and ball tip shapes
- Standard and extension lengths
- For hex-locking and non hex-locking pencils
- High-count cases for volume services
Browse the full Electrosurgery range, or shop everything from Medtronic.
Main Description
This listing is Valleylab's stainless steel electrode range, the uncoated workhorse tips for monopolar pencils. Blade electrodes in 2.44 inch length fit hex-locking and non hex-locking pencils, and a needle electrode covers fine work. The 5 mm ball electrode serves broad coagulation and fulguration where a blade would cut instead. Extension blade and extension needle electrodes at 6.5 inches reach deep operative fields. All configurations are single use and supplied in cases of 50 or 150 as labeled, the high counts volume electrosurgery services consume.
Features and Benefits
- Three tip geometries – Blade for cutting, needle for precision, ball for coagulation: the full monopolar tip kit.
- Extension reach – Six and a half inch versions bring monopolar energy to deep fields without a specialty pencil.
- Pencil compatibility – Hex-locking and standard shank versions match the Valleylab pencil fleet.
- Volume packaging – Cases up to 150 suit high-throughput services and keep unit cost down.
Product Specifications
Product Facts
| Device Type | Stainless steel electrosurgical electrodes |
| Tip Shapes | Blade, needle, ball (5 mm) |
| Lengths | 2.44 in standard. 6.5 in extensions |
| Compatibility | Valleylab hex-locking and standard pencils as labeled |
Packaging and Configurations
| Use | Single use |
| Package | 50 or 150 per case as labeled |
Product Line
| Brand | Medtronic |
| Product Family | Valleylab stainless steel electrode |
Distribution
| Availability | Continental US |
| Package Quantity | cs (per configuration as listed) |
Why Choose This Product
Every electrosurgery service burns through stainless tips daily. This is the genuine Valleylab range in the counts that match consumption. Ball and extension tips in the same listing stop the piecemeal ordering that leaves trays short.
- Complete tip kit – Cutting, precision and coagulation tips in one listing is the stocking differentiator.
- Deep field reach – Extensions serve bariatric and deep pelvic work with standard pencils.
- Economical volume – High-count cases fit the burn rate of busy services.
Frequently Asked Questions
When is a ball electrode used instead of a blade?
The ball spreads energy over a round contact for coagulation and fulguration of broader surfaces, while the blade concentrates energy at an edge for cutting. Surgeons swap tips as the task changes within a case.
Are these electrodes sterile?
The configurations are supplied for single use in sterile procedure settings as labeled. Check the variant label for its exact sterile presentation and count.
Is this device sterile and single use?
Yes. It is supplied sterile for single use unless its label states otherwise, and it must not be reprocessed or reused. Check the package integrity and expiry before every case.
How should this device be stored?
Store it in its original packaging under normal room conditions away from heat sources and moisture. Rotate stock by expiry date and quarantine any unit with damaged packaging.
What if a configuration I need is not listed?
The configurations shown are the ones carried in this catalog for this product line. If a case needs a different size or load, contact us before ordering so the right configuration can be confirmed rather than substituted at the table.