Description
The Welch Allyn Masimo RED LNC-10 Cable is a Masimo RED LNC-10 patient cable connecting LNCS sensors to Welch Allyn Connex monitors equipped with Masimo SpO2. It suits facilities running Connex monitors with Masimo oximetry whose patient cable has worn, loosened or gone intermittent.
- RED LNC-10 Pattern – the cable is the Masimo LNCS patient cable pattern the Connex Masimo channel uses
- For Connex Masimo Monitors – it serves Welch Allyn Connex monitors fitted with Masimo SpO2
- Sensor Link – LNCS reusable and disposable sensors connect through this cable
The Cable Between Connex and Its Masimo Sensors
Connex monitors with Masimo oximetry read through a chain of sensor, patient cable and monitor, and the cable is the middle link that flexes most. This RED LNC-10 cable is the LNCS patient cable for that chain. When SpO2 readings drop out or search endlessly, a worn patient cable is a prime suspect after the sensor itself. Replacing the cable restores the link without replacing sensors that still read well on a known good cable. Facilities standardize the cable so any LNCS sensor on the unit works at any Connex Masimo monitor.
Features and Benefits
Cable Design
- LNCS Patient Cable: The RED LNC-10 connects LNCS sensors to the monitor.
- Masimo SpO2 Channel: It serves the Masimo oximetry option on Connex monitors.
Service Use
- Dropout Repair: It replaces cables causing intermittent SpO2 signal loss.
- Sensor Compatibility: LNCS reusable and adhesive sensors connect through it.
Product Specifications
Product Details
- Product Type: SpO2 patient cable
- Pattern: Masimo RED LNC-10, LNCS
- Compatibility: Welch Allyn Connex monitors with Masimo SpO2
Packaging
- Package Contents: one RED LNC-10 patient cable
Reference
- Manufacturer SKU: RED LNC-10
Browse the full Professional Use range, or shop everything from Welch Allyn.
Why the Patient Cable Is Its Own Spare
Sensors get blamed for cable faults because the cable fails quietly inside its own insulation. This genuine Masimo pattern cable restores the Connex SpO2 link in the exact LNCS specification.
- Stable Readings – sound conductors end cable caused dropouts and searching
- LNCS Standard – the unit's existing sensors keep working through the new cable
- Targeted Repair – the cable swaps alone when sensors prove good
Frequently Asked Questions
What is this patient cable used for?
It connects between a Connex monitor's Masimo SpO2 channel and an LNCS sensor on the patient. It replaces worn or intermittent patient cables.
Does it include a sensor?
No. This is the patient cable. LNCS finger sensors, reusable or adhesive, are separate parts that plug into it.
How is this product sold?
The listing is for one each: one RED LNC-10 patient cable, the price applies to the full each, with counts detailed in the specifications above.
Will it work with Nellcor Connex monitors?
No. This cable serves the Masimo SpO2 option. Connex monitors with Nellcor oximetry use a different cable pattern.
Is this the genuine Welch Allyn product?
It is. The patient cable is sourced and listed as the genuine Welch Allyn item, and its manufacturer SKU, RED LNC-10, is printed in the specifications for verification on arrival.
How do I test whether the cable is the fault?
Try the suspect sensor on a known good cable, and a known good sensor on the suspect cable. The combination that fails names the faulty link.