Description
The Wellell Optima Turn Lateral Rotation Mattress turns patients automatically to the 30-degree lateral position that clinical guidelines recommend, on a schedule the care team sets once. Anyone who has done two-hour manual turns through the night knows the strain it puts on staff backs and on patient sleep, and this surface takes that load off both. It is built for intensive care and long-term care patients at high to very high risk who need consistent repositioning.
- Programmed Lateral Turning – Automatic turns to 30 degrees run on a timer, so repositioning happens on schedule even on short-staffed nights.
- Alternating Pressure During Turns – Alternation keeps working while the patient is turned, protecting the hips, sacrum and trochanters through every position.
- Protective Side Bolsters – Firm bolster cells cushion the patient against the bed rails and include a lowered mid-section that leaves room for drainage tubes.
- Individual Heel Cell Deflation – Single heel cells deflate on demand for true zero-pressure heel relief, easing one of the most injury-prone areas.
Programmed Turns That Follow the Guideline Schedule
Guidelines call for repositioning every 2 to 4 hours, with the 30-degree lateral position preferred over a full 90-degree side lie. This mattress builds that schedule into the surface itself, rotating the patient gently from side to side with dwell times the caregiver selects. Alternating pressure runs as part of the turning mode rather than pausing for it, so pressure redistribution never stops. One caregiver can supervise a turn that once took two or three people, which reduces handling injuries and keeps the turning record consistent. For bedbound and immobile patients, that consistency is the difference between a plan on paper and prevention in practice.
Features and Benefits
Turning and Pressure Relief
- Automatic and Assisted Turning Modes: Timer-controlled rotation to 30 degrees supports scheduled repositioning without manual lifting.
- Alternating Cells Matched to the Bodyline: Air cells follow the body through the turn so pressure mapping stays even across positions.
- Cell-in-Cell Sacrum Support: Reinforced sacrum cells hold support and stability during sitting and transfers.
Patient Safety and Comfort
- Side Bolster Protection: Bolsters keep the patient from pressing directly against side railings while adding comfort in the turned position.
- Customizable Heel Relief: Individually deflatable heel cells let caregivers offload the heels completely for fragile skin.
- Seating Support Mode: Inflated seating support adds stability and helps prevent bottoming out when the patient sits up.
Product Specifications
Mattress Specifications
- Mattress Type: Replacement
- Mattress Dimensions: 78.7 x 36 x 8 in (200 x 91.4 x 20.3 cm)
- Maximum Patient Weight: 397 lb (180 kg)
- Turning Angle: Up to 30 degrees lateral rotation
- Cell Material: Thermoplastic polyurethane (TPU)
Pump and Therapy Specifications
- Therapy Modes: Alternating pressure with automatic or assisted turning
- Cycle Times: 10, 15, 20 or 25 minutes
- Dwell Times: 10, 20, 30 or 60 minutes
- HCPCS Code: E0277
- Warranty: 2 years on pump, 2 years on mattress
Browse the full Air Mattress Systems range, or shop everything from Wellell.
Why Scheduled Turning Protects Skin Around the Clock
Manual turning programs fail quietly, because one missed turn on a busy night is enough to start tissue damage in a high-risk patient. Optima Turn makes the schedule automatic, so the guideline program runs the same way on every shift. Caregivers get their backs and their hours back, and patients rest through turns instead of being woken for them.
- Guideline Angle Built In – Turns stop at the recommended 30-degree lateral position, not a full side lie that loads the trochanter.
- One-Caregiver Turns – Automated rotation cuts the team needed from two or three staff to one, easing strained rosters.
- Relief That Never Pauses – Alternation is part of the turning mode itself, so offloading continues through every position change.
- Heel Attention – Deflatable heel cells protect the spot where pressure injuries often start first.
Manuals and Troubleshooting Guides
Wellell Optima Turn Lateral Rotation Mattress – Product Brochure
Frequently Asked Questions
How long does a turn from one side to the other take?
A full change from left turn to right turn takes about 3 to 5 minutes. The patient’s body mass and contour influence the exact duration, with heavier patients taking a little longer.
Can the alternating mode be switched off during turning?
No, alternating pressure is part of the default turning mode and stays active by design. That keeps pressure redistribution running continuously instead of pausing during each reposition.
What happens right after the mattress is switched on?
The air cells inflate automatically to maximum firmness when the system powers on. If no mode is selected within the first 10 minutes, the pump moves into alternating pressure mode on its own.
Which patients is this surface intended for?
It suits bedbound and immobilized patients at medium to high risk, especially where the scapulae and greater trochanters are vulnerable. Units use it across intensive care, neurology and long-term care settings.
What warranty covers the system?
The manufacturer covers the pump for 2 years and the mattress for 2 years. Register the unit on arrival so any later service request can be matched to the purchase quickly.