Description
The AllFLOW One-Way Expiratory Mouthpiece lets a patient blow a full, forceful breath into a peak flow meter or spirometer with no chance of inhaling back through the equipment. Its one-way valve opens on exhalation and closes against the return flow, which protects both the patient and the instrument from cross-contamination.
- Red color coding marks it as the expiratory mouthpiece
- Fits standard peak flow meters and spirometers
- Single patient use, with no cleaning or sterilization
- Varnished, non-absorbent finish for patient comfort
A One-Way Barrier for Every Expiratory Maneuver
During expiratory testing the patient exhales forcefully into the meter, and the valve in this mouthpiece passes that breath in one direction only. Because the patient cannot inhale through the mouthpiece or the equipment behind it, the pathway stays one way from start to finish. That single design point is what makes the mouthpiece a cross-infection control rather than a plain paper tube. The red printing identifies the expiratory version at a glance, even in a busy testing room.
Alliance Tech Medical prints its name and the part number directly on each mouthpiece, so staff can verify the part in hand against the order. The varnished, non-absorbent finish keeps the surface comfortable against the lips through repeated blows in one session, and when the session ends the mouthpiece is discarded so the equipment stays clean for the next patient.
Features and Benefits
Cross-Infection Control
- One-Way Valve: Passes exhaled air and blocks inhalation through the mouthpiece
- Single Patient Use: Discarded after one patient, saving sterilization time and cost
- Color Coding: Red printing identifies the expiratory version
Fit and Comfort
- Equipment Fit: Fits standard peak flow meters and spirometers
- Surface Finish: Varnished and non-absorbent, with no sticking to lips
- Patient Range: Adaptable for adult or pediatric use
Product Specifications
Product Details
- Brand: AllFLOW
- Manufacturer: Alliance Tech Medical
- Model Number: 3122064
- Product Type: One-Way Valved Mouthpiece, Expiratory
- Sold As: SKU 3122064, box of 200
Use
- Direction: Expiratory use only
- Resistance: Very low, and it does not alter readings
Browse the full Hospital Supplies range for related spirometry testing supplies. The Alliance Tech Medical brand page covers the rest of the AllFLOW mouthpiece and accessory line.
Why Testing Rooms Stock the Red Expiratory Mouthpiece
Expiratory maneuvers are the core of peak flow and spirometry testing, and they are the moment a bare tube offers no protection at all. This mouthpiece puts a true one-way barrier at the lowest cost point in the workflow, the disposable itself.
- Protection Built Into the Consumable: The valve does the work, so staff add no extra steps
- No Reading Penalty: Very low resistance keeps meter and spirometer readings true
- Instant Identification: Red printing separates expiratory stock from inspiratory stock on the shelf
Manuals and Troubleshooting Guides
Frequently Asked Questions
What does the one-way valve do?
The valve opens when the patient exhales into the meter and closes against any return flow. The patient therefore cannot inhale through the mouthpiece or the equipment attached to it. That one-way path is the cross-infection protection.
Which equipment does it fit?
It fits standard peak flow meters and spirometers used for expiratory maneuvers. The mouthpiece is sized for the standard mouthpiece port on those instruments. Confirm the fit on your meter before a testing session.
Can it be reused for the same patient?
Each mouthpiece serves one patient and goes out with the session waste. Nothing about it is washed, sterilized or returned to stock. The box of 200 keeps testing rooms supplied.
How do staff tell it from the inspiratory mouthpiece?
The expiratory mouthpiece is printed in red and marked Expiratory with its part number. The inspiratory version is printed in blue. The color coding keeps the two from being mixed up.
Does the valve change the reading?
No, Alliance Tech Medical rates the resistance as very low and states that it does not alter readings. The valve passes a forceful exhalation freely. Only the return path is blocked.