Description
The AllFLOW One-Way Inspiratory Mouthpiece lets a patient draw a free, full breath in through an In-Check or In-Check DIAL while its one-way valve keeps exhaled air out of the instrument. That protection is what allows one training device to serve patient after patient through a clinic day.
- Blue color coding marks it as the inspiratory mouthpiece
- Made for the In-Check and In-Check DIAL training devices
- Single patient use, with no cleaning or sterilization
- Varnished, non-absorbent finish for patient comfort
Clean Inspiratory Training on a Shared In-Check DIAL
Inspiratory technique training asks the patient to inhale through the meter again and again while the clinician coaches force and flow. With a plain mouthpiece, every exhalation between attempts would go straight back into the shared instrument. The valve in this mouthpiece passes the inward breath freely and blocks the outward one, so the In-Check stays protected across a full clinic of trainees. The blue printing identifies the inspiratory version at a glance.
Alliance Tech Medical prints its name and the part number directly on each mouthpiece, so staff can verify the part in hand against the order. The varnished, non-absorbent finish keeps the surface comfortable against the lips through repeated practice breaths, and when the training session ends the mouthpiece is discarded so the dial is ready for the next patient.
Features and Benefits
Cross-Infection Control
- One-Way Valve: Passes inhaled air and prevents the patient from exhaling into the meter
- Single Patient Use: Discarded after one patient, saving sterilization time and cost
- Color Coding: Blue printing identifies the inspiratory version
Fit and Comfort
- Equipment Fit: For use with the In-Check and In-Check DIAL
- Surface Finish: Varnished and non-absorbent, with no sticking to lips
- Patient Range: Adaptable for adult or pediatric use
Product Specifications
Product Details
- Brand: AllFLOW
- Manufacturer: Alliance Tech Medical
- Model Number: 3122069
- Product Type: One-Way Valved Mouthpiece, Inspiratory
- Sold As: SKU 3122069, box of 200
Use
- Direction: Inspiratory use only
- Resistance: Very low, and it does not alter readings
Browse the full Hospital Supplies range for related inhaler training supplies. The Alliance Tech Medical brand page covers the rest of the AllFLOW training and testing line.
Why Trainers Pair the Blue Mouthpiece with the In-Check DIAL
The In-Check DIAL is a multiple patient use instrument, so its hygiene depends entirely on the mouthpiece in front of it. This mouthpiece is the manufacturer specified barrier for that job, printed with the part number the training kits call for.
- Specified for the Device: The In-Check DIAL kits list this exact mouthpiece as their inspiratory option
- No Reading Penalty: Very low resistance keeps inspiratory flow readings true
- Instant Identification: Blue printing separates inspiratory stock from expiratory stock on the shelf
Manuals and Troubleshooting Guides
Frequently Asked Questions
What does the one-way valve do?
The valve opens as the patient inhales through the meter and closes against the return breath. The patient therefore cannot exhale back into the In-Check or In-Check DIAL. That one-way path protects the shared instrument.
Which devices does it fit?
It is made for the In-Check and In-Check DIAL inspiratory training devices. The mouthpiece adapts for adult or pediatric use. Confirm the fit on your device before a training session.
Can it be reused for the same patient?
Each mouthpiece serves one trainee and is thrown away when the session ends. Because it is disposable, no reprocessing step follows the training. The box of 200 keeps training clinics supplied.
How do staff tell it from the expiratory mouthpiece?
The inspiratory mouthpiece is printed in blue and marked Inspiratory with its part number. The expiratory version is printed in red. The color coding keeps the two from being mixed up.
Does the valve change the reading?
No, Alliance Tech Medical rates the resistance as very low and states that it does not alter readings. The valve passes a full inhalation freely. Only the return path into the meter is blocked.