Description
B&F Medical Softie Nasal Cannula is an over-the-ear nasal cannula from B&F Medical with soft prongs and Sure Flow crush-resistant tubing for low-flow oxygen delivery. The anti-roll guard holds the prongs in position, which keeps oxygen delivery steady when the patient turns in bed or ambulates.
- Soft prongs for patient comfort
- Anti-roll guard holds position
- Sure Flow crush-resistant tubing
- 4 ft, 8 ft and 25 ft lengths
Low-Flow Oxygen That Stays in Place
Cannula comfort decides whether patients keep their oxygen on, and the Softie line answers with softer prongs and a connector shaped to sit comfortably at the nose. The anti-roll guard is the detail that matters at night: it keeps the prong assembly from rotating out of the nares when the patient rolls onto the tubing. Sure Flow tubing resists the kinks and crush points that interrupt flow when tubing runs under a patient or through a bed rail. Three lengths cover the work, from the 4 ft bedside length to the 25 ft length that lets a patient move around a room on one connection.
Features and Benefits
- Style: Over-the-ear with anti-roll guard
- Prongs: Soft prongs for extended wear
- Tubing: Sure Flow crush-resistant oxygen tubing
- Lengths: 4 ft, 8 ft and 25 ft, by model
- Use: Single-patient disposable
Product Specifications
Identification
- Manufacturer: B&F Medical (Allied Healthcare)
- Product Line: Softie nasal cannulas
Complete the workstation with matching pieces from Hospital Supplies and the wider Allied Healthcare catalog, all stocked at MedicalEx.
Why Home-Care Programs Stock Softie Cannulas
Comfort and position are the two reasons cannulas fail patients, and the Softie design addresses both in one inexpensive disposable. The length range means one product family covers the bed, the chair and the hallway.
- Soft prongs patients tolerate for hours
- Anti-roll guard prevents displacement
- Crush-resistant tubing protects flow
- Three lengths for bed to room mobility
Manuals and Troubleshooting Guides
Frequently Asked Questions
What does the anti-roll guard do?
It is a shaped section behind the prongs that keeps the cannula from rotating when the patient moves. The prongs stay seated in the nares instead of rolling out.
Which length should I order?
Choose 4 ft for bedside and chair use near the source, 8 ft for standard room setups, and 25 ft when the patient needs to move around the room. See the specification section above for the full part 33208 listing.
Is the tubing crush resistant?
Yes. Sure Flow tubing is designed to resist kinking and crushing that would otherwise interrupt oxygen flow.
Are the cannulas reusable?
No. They are single-patient disposables replaced on the schedule your care program sets.
What flow rates suit a standard cannula?
Standard nasal cannulas serve low-flow oxygen therapy, commonly 1 to 6 lpm as prescribed. Follow the ordering clinician direction for each patient.