null
HemoCue

HemoCue Hb 801 Analyzer – Hemoglobin Results in Under 1 Second with Bluetooth Connectivity, Each

(No reviews yet) Write a Review
SKU:
121920
MPN:
121920
Shipping:
Calculated at Checkout
  • HemoCue Hb 801 Analyzer – Hemoglobin Results in Under 1 Second with Bluetooth Connectivity, Each
  • HemoCue Hb 801 Analyzer – Hemoglobin Results in Under 1 Second with Bluetooth Connectivity, Each
  • HemoCue Hb 801 Analyzer – Hemoglobin Results in Under 1 Second with Bluetooth Connectivity, Each
  • HemoCue Hb 801 Analyzer – Hemoglobin Results in Under 1 Second with Bluetooth Connectivity, Each
$852.99
Fast Delivery
Fast Delivery
Most ship in 1–2 days
Shipping
$50+ Ship Free
Flat $6.95
30-Day Returns
30-Day Returns
No questions asked
Secure Payment
Secure Payment
100% safe checkout

Description

The HemoCue Hb 801 Analyzer returns a hemoglobin result in under one second from a 10 µL sample. Bluetooth and USB connectivity move results into the record without a docking station. The rechargeable-ready design and wide operating range suit busy clinics, donor centers and field programs.

  • Under-one-second results – the fastest measuring time in the HemoCue hemoglobin line
  • Wireless transfer – Bluetooth Low Energy and USB interfaces for result management
  • Wide operating range – rated for 50 to 104°F (10 to 40°C) environments

The Fastest Hemoglobin Workflow HemoCue Has Built

The system measures absorbance of whole blood at an Hb/HbO2 isosbestic point inside the analyzer, with the microcuvette drawing blood in by capillary action. Calibration is traceable to the HiCN reference method, and the range of 1.0 to 25.6 g/dL covers the values clinicians act on. The analyzer weighs under 250 g and runs on three AA batteries, a USB adapter or the optional rechargeable battery. A large display and simple three-step workflow reduce training time for new operators. Built-in self-test and optional liquid controls support documented quality programs.

Features and Benefits

Testing Performance

  • Sub-second measurement – results in less than 1 second keep high-volume screening moving
  • Isosbestic-point optics – absorbance measured at an Hb/HbO2 isosbestic point
  • Clinical range – 1.0 to 25.6 g/dL for screening and monitoring

Connectivity and Power

  • Bluetooth and USB – wireless or cabled result transfer without a docking station
  • Flexible power – 3 AA batteries, USB adapter or the optional rechargeable battery
  • Featherweight build – under 0.55 lb for tray, cart and field use

Product Specifications

Measurement

  • Principle: Absorbance of whole blood measured at an Hb/HbO2 isosbestic point
  • Calibration: Calibrated against the hemiglobincyanide (HiCN) reference method recommended by the ICSH
  • Measurement range: 1.0 to 25.6 g/dL (10 to 256 g/L, 0.62 to 15.9 mmol/L)
  • Measuring time: Less than 1 second
  • Sample material: Capillary or venous whole blood
  • Sample volume: 10 µL

Handling and Storage

  • Dimensions: 3.5 x 5.6 x 9 in (87 x 143 x 45 mm)
  • Weight: Under 0.55 lb (250 g), batteries excluded
  • Interface: USB and Bluetooth Low Energy
  • Power: USB adapter or 3 AA batteries, optional rechargeable battery
  • Operating temperature: 50 to 104°F (10 to 40°C)

Why High-Volume Sites Move to the Hb 801

When hundreds of hemoglobin tests run in a day, seconds per test decide whether screening keeps up. This analyzer cuts the measurement itself to under a second and removes the docking step with wireless transfer, so throughput is set by sampling, not by the instrument.

  • Throughput that scales – sub-second results clear screening lines faster than any earlier HemoCue model
  • No dock required – Bluetooth transfer sends results onward from wherever testing happens
  • Broad environment range – a 10 to 40°C operating window covers clinics, mobile units and field sites

Manuals and Troubleshooting Guides

Frequently Asked Questions

Which microcuvettes does it use?

It uses the Hb 801 Microcuvettes, stocked separately in the 200-count package.

How do results reach the patient record?

The analyzer connects by Bluetooth Low Energy or USB, so results transfer without a docking station.

Does it need calibration?

No. The system is factory calibrated against the HiCN reference method and needs no further calibration.

What powers the analyzer?

It runs on three AA batteries, a USB adapter, or the optional HemoCue rechargeable battery.

What package is sold here?

This listing is for the analyzer alone, sold as listed in the Each package configuration. Microcuvettes are stocked separately.

View AllClose

Warranty Information

This product may be covered under the manufacturer's original warranty. Please refer to the manufacturer's documentation or contact us for assistance.
View AllClose

0 Reviews

View AllClose

Explore our wide range of medical products, enjoy hassle-free shopping, and take advantage of our exclusive offers. Free shipping on orders over $50! Need assistance? Contact our friendly customer support team at (800) 494-5750. Happy shopping!