Description
HTL-Strefa Medlance Plus Safety Lancets organize nine configurations by color, so the depth and gauge a protocol calls for is the color the hand reaches for. Depths run from a gentle 1.2 mm at 30G to a full 2.4 mm at 21G, plus a blade model for high flow. Clinics standardize on the color system across departments.
- Color-Coded Depths – Light green, purple, blue, green and yellow bodies encode depth and gauge for instant selection.
- Widest Depth Ladder – Five depth steps from 1.2 mm to 2.4 mm cover pediatric-gentle through high flow sampling.
- Needle and Blade – Eight needle models plus a 0.8 mm blade model for the deepest draws.
- Two Box Counts – Most depths come in both 100 and 200 count boxes.
Medlance Plus Safety Lancets with Color-Coded Depths
Depth is the variable that decides whether a capillary sample flows or fails. This line turns depth selection into a color system: light green for 1.2 mm at 30G, purple for 1.5 mm at 25G, blue for 1.8 mm at 21G, green for 2.4 mm at 21G, and yellow for the 0.8 mm blade at 2.0 mm. The devices are sterile, single use and gamma sterilized, inside the manufacturer's FDA-cleared safety lancet family. Laboratories and clinics that run several sampling protocols keep the full color ladder at the bench. Consistent color coding cuts selection errors when staff rotate.
Features and Benefits
Safety Mechanism
- Shielded Point – The needle or blade stays covered before and after firing, and the spent device locks.
- Single-Use Format – Each device samples once and is discarded, no cleaning or device sharing.
Sampling Range
- Five Depths – 1.2, 1.5, 1.8, 2.0 blade and 2.4 mm depths span the practical capillary range.
- Gauge Range – Needles run 30G, 25G and 21G across the depth ladder.
Product Specifications
Device Details
- Models: 30G at 1.2 mm (light green), 25G at 1.5 mm (purple), 21G at 1.8 mm (blue), 21G at 2.4 mm (green), 0.8 mm blade at 2.0 mm (yellow)
- Sterility: Gamma sterilized, sterile single use
Packaging
- Packaging: Boxes of 100 or 200 lancets by model, as the variant labels state.
Explore More: See all Lancets & Lancing Devices | Shop more HTL-Strefa Products
Why Choose Medlance Plus
Sampling protocols fail at the selection step more often than at the stick. A color system that encodes depth and gauge makes the right device the obvious one, across every bench and shift.
- Selection by Color – Staff pick by color against the protocol, fewer wrong-depth draws.
- Full Ladder in One Line – Five depths and a blade keep every protocol inside one stocked family.
- Bench Consistency – The same color system in every department simplifies training and audits.
Frequently Asked Questions
Is each lancet sterile?
Yes. Every device is gamma sterilized and sterile at the point of use. Each lancet samples once and is discarded.
How does the shielding work?
The point stays covered until the firing moment and retracts or locks afterward. A spent device cannot fire again and goes to sharps disposal.
Which color should I choose?
Match the color to the protocol depth: light green 1.2 mm for gentle draws and green 2.4 mm for the deepest needle draws. The yellow blade at 2.0 mm serves high flow sampling.
Who are safety lancets for?
Laboratories, clinics and home testers use them wherever exposed lancet points are a risk. Single use removes cleaning and device sharing from the routine.
What are the box counts?
Boxes of 100 or 200 lancets by model, as the variant labels state. Boxes are the sellable unit on this listing.