null
Medtronic

Medtronic Flexon Temporary Cardiac Pacing Lead – Stainless Steel Wire for Pacing After Cardiac Surgery

(No reviews yet) Write a Review
$688.99 - $1,243.99
Shipping:
FREE standard shipping (contiguous US)
$688.99 - $1,243.99
Fast Delivery
Fast Delivery
Most ship in 1–2 days
Shipping
$50+ Ship Free
Flat $6.95
30-Day Returns
30-Day Returns
No questions asked
Secure Payment
Secure Payment
100% safe checkout

Description

The Medtronic Flexon Temporary Cardiac Pacing Lead is a twisted stainless steel wire lead built for temporary atrial and ventricular pacing and sensing during and after cardiac surgery. Eight double-needled configurations cover sizes 0, 2-0 and 3-0, each pairing a straight needle with a curved needle on a 24 inch lead.

  • Twisted Multistrand Wire – stainless steel strands are twisted together and coated, giving the lead its strength and handling
  • Two Needles on Every Lead – a straight needle and a curved taper point needle come affixed to each double-armed lead
  • Designed for Gentler Removal – the insulated lead is designed to be less traumatic when it is withdrawn after pacing ends

Pacing and Sensing Support for the Days After Open Heart Surgery

Temporary pacing leads are placed while the chest is open, then relied on through the first days of recovery when the heart's own rhythm may falter. The Flexon lead answers that need with a stainless steel wire that is twisted from multiple strands rather than drawn as a single filament. A PTFE or FEP coating insulates the wire along its length, and Medtronic designs the lead to come out with less trauma once pacing is no longer needed. Each configuration is double armed, pairing a straight needle at one end with a curved taper point needle at the other. The result is one sterile lead that the surgical team can place, connect and later remove as a single unit.

Features and Benefits

Lead Construction

  • Twisted Multistrand Stainless Steel Wire: The lead is twisted from stainless steel strands for strength and handling in the surgical field.
  • PTFE or FEP Coating: Coating options include orange or white PTFE and clear FEP, insulating the lead along its length.
  • Permanent Tensile Strength: The non-absorbable wire keeps its tensile strength for the full pacing period.
  • Minimal Tissue Reaction: The lead elicits minimal acute inflammatory reaction in tissues and is not absorbed.

Needle Configurations

  • Double-Armed Needle Pairs: Every configuration carries a straight needle and a curved half circle taper point needle on the same lead.
  • Three Suture Sizes: Configurations cover USP sizes 0, 2-0 and 3-0 to match the surgeon's placement preference.

Product Specifications

Product Details

  • Product Line: Flexon Temporary Cardiac Pacing Leads
  • Material: Stainless steel twisted multistrand wire
  • Coating: Orange or white PTFE, or clear FEP
  • Indication: Temporary atrial and ventricular pacing and sensing during and after cardiac surgery
  • Sterilization: Ethylene oxide
  • Sterility: Supplied sterile

Sizes and Ordering

  • Lead Length: 24 inches on every configuration in this listing
  • Size Range: USP 0, 2-0 and 3-0
  • Needle Combinations: Straight SC, SC-2 or SC-6 paired with curved CV-23, CV-24 or V-20
  • Packaging: 1 dozen per box
  • Item Numbers: 8886259363-2, 8886259763, 8886258963, 8886262353, 8886261553, 8886259143-2, 8886259243-2, 8886258643-2

Browse the full Suture and Needles range, or shop everything from Medtronic.

Why Choose the Medtronic Flexon Temporary Cardiac Pacing Lead?

Postoperative pacing is not the moment for improvisation at the bedside. This lead gives the cardiac team a purpose-built wire, insulated for its run and needled at both ends, ready to place before the chest closes. When recovery steadies, the same lead is designed to withdraw with less trauma than an uninsulated wire.

  • Rhythm Backup After Surgery – temporary pacing and sensing cover the heart while its own conduction recovers
  • Less Traumatic Removal – the insulated design targets a gentler withdrawal once pacing is complete
  • Eight Ready Configurations – sizes and needle pairs are stocked as distinct options, so the team orders the exact lead the surgeon prefers

Frequently Asked Questions

What is this lead used for?

It is indicated for temporary atrial and ventricular pacing and sensing during and after cardiac surgery. The lead is placed in the operating room and supports the heart's rhythm through the early recovery period.

What is the lead made of?

The lead is a twisted multistrand stainless steel wire. It is coated with orange or white PTFE or with clear FEP, which insulates the wire along its length.

Which needle combinations are available?

Every configuration is double armed with a straight needle and a curved needle. Straight SC, SC-2 and SC-6 needles pair with curved CV-23, CV-24 and V-20 taper point needles across the eight configurations.

What sizes does it come in?

Configurations cover USP sizes 0, 2-0 and 3-0. Every lead in this listing is 24 inches long, and the coating color varies by configuration.

How is the lead supplied?

Each configuration is supplied sterile and sterilized by ethylene oxide. Leads are packaged one dozen per box, ready for the operating room.

Does the lead stay in permanently?

No. It is a temporary lead, placed for pacing during and after surgery and removed when pacing is no longer needed, and its tensile strength is rated permanent for the period it is in place.

View AllClose

Warranty Information

This product may be covered under the manufacturer’s original warranty. Please refer to the manufacturer’s documentation or contact us for assistance.
View AllClose

0 Reviews

View AllClose

Explore our wide range of medical products, enjoy hassle-free shopping, and take advantage of our exclusive offers. Free shipping on orders over $50! Need assistance? Contact our friendly customer support team at (800) 494-5750. Happy shopping!