Description
Nonin Nurse Call Cables for Avant Pulse Oximeters, 2 m and 3 m with Phone Plug and 3 m Blunt Cut
The Nonin Nurse Call Cables connect an Avant oximeter's alarm output to the facility nurse call system. When the monitor alarms, the call system lights as well, so an event is visible beyond the room.
- Connects Avant oximeter alarms to the nurse call system
- Two plug terminated lengths, 2 m and 3 m, with 1/4 in phone plug
- A 3 m blunt cut version for hardwired installations
- Manufacturer cable parts 4076-001, 4076-002 and 4076-003
Nurse Call Cables for Avant Alarm Integration
An alarm nobody hears is a monitoring gap, and nurse call integration closes it for tabletop monitoring. These cables carry the Avant 9600's alarm state to the facility call system, lighting the corridor indicator when the monitor alarms. The Avant specification supports a normally open or normally closed output, switch selectable, through its miniature phone jack connector. Plug terminated versions connect directly where the call system accepts a 1/4 inch phone plug. The blunt cut version suits hardwired installations where the cable is terminated on site. Rated limits per the monitor specification are 30 volts AC or DC at up to 100 milliamps.
Features and Benefits
Alarm Integration
- Call System Link – monitor alarms appear on the facility nurse call system.
- Selectable Output – normally open or normally closed operation per the monitor specification.
- Two Termination Styles – phone plug for direct connection, blunt cut for hardwiring.
Options
- Three Configurations – 2 m plug, 3 m plug and 3 m blunt cut versions.
- Rated Connection – 30 V AC or DC maximum, 100 mA maximum load per specification.
- OEM Cables – manufacturer parts in the 4076 series.
Product Specifications
Function
- Purpose: Nurse call alarm output connection for Avant oximeters
- Monitor Output: 0.141 in miniature phone jack, normally open or closed, switch selectable
- Ratings: 30 V AC or DC maximum voltage, 100 mA maximum load current
- Compatible Devices: Nonin Avant tabletop pulse oximeters with nurse call output
Configuration
- Options: 2 m with plug, 3 m with plug, 3 m blunt cut
- Manufacturer Parts: 4076-001, 4076-002, 4076-003
- Package: Sold individually by configuration
- Category: Oximeter accessory, cable
See all Oximeter Accessories for the full range, or Shop more Nonin Products for the complete line.
Why Facilities Wire Avant Alarms into the Call System
Tabletop monitors often watch patients in rooms that are not continuously staffed. A nurse call link makes the monitor's alarm a facility event instead of a sound in an empty room.
- No Silent Alarms – alarm states surface on the call system staff already watch.
- Installation Choice – plug or blunt cut versions match the building's wiring.
- Specified Ratings – the cable and output follow the monitor's published limits.
- Simple Retrofit – one cable upgrades an existing Avant installation.
Frequently Asked Questions (FAQs)
What do nurse call cables do?
They connect the Avant oximeter's alarm output to the facility nurse call system, so monitor alarms also activate the call indicator. That gives staff a second, corridor level indication of the alarm.
Which configuration should I choose?
Choose a plug version where the call system accepts a 1/4 inch phone plug, in 2 m or 3 m length. Choose the blunt cut 3 m version for hardwired termination on site.
What are the output ratings?
Per the Avant specification, the nurse call output is rated to 30 volts AC or DC at up to 100 milliamps, and is switch selectable between normally open and normally closed. Those ratings come from the monitor manufacturer published specification.
Which monitors have this output?
The Avant tabletop line provides the nurse call output used with these cables. Check your monitor's connector before ordering.
Are the cables sold individually?
Yes. Each configuration is its own part number and is sold singly.