Description
The Sensoronics SS-14A Medical Oxygen Sensor is a galvanic oxygen cell that replaces the Dräger 6850645 sensor in anesthesia machines, ventilators and oxygen analyzers.
Oxygen readings anchor anesthesia and ventilation decisions, and a cell at the end of its life drifts quietly, so planned replacement keeps the numbers honest.
- Galvanic Fuel Cell – The electrochemical cell generates a current in proportion to oxygen partial pressure, so the host machine reads oxygen directly from the cell output.
- Dräger 6850645 Replacement – Built as the compatible replacement for the Dräger 6850645 and 6803290 sensors, so the swap follows the original service routine.
- Anesthesia and Ventilator Fit – The cell serves Dräger Narkomed, Babylog, Evita and Fabius lines, so one cell covers the anesthesia and ICU fleets.
- 12-Month Unconditional Warranty – The manufacturer backs the cell with a 12-month unconditional warranty, so a short-lived cell is covered.
The Galvanic Cell Behind Accurate Oxygen Readings
Medical oxygen sensors are consumables with a finite life: the galvanic cell reacts with oxygen, and output fades as the cell ages. The SS-14A is Sensoronics’ replacement cell for the Dräger 6850645, the sensor behind oxygen monitoring on Narkomed anesthesia machines, Babylog ventilators and the Evita line. Biomed teams swap the cell on the machine’s service schedule and calibrate at 100% oxygen per the manufacturer guide.
The cell also cross-references to Analytical Industries PSR-11-915-2, C&S G0-020, City Technology MOX-16, Envitec OOM201, Datex-Ohmeda 6051-0000-224, Hamilton HM-14, Hudson RCI 5557, Maxtec MAX-11, Mercury Medical 10-103-07, MSA 655263, Teledyne R-23MED and VTI 103122. Compatible hosts include the Dräger Narkomed 1A, 2, 2B, 3, 4 and 6000, Babylog 8000, Evita, Evita 2, Evita 4, Evita XL and Evita 2 Dura, Fabius and Fabius GS, plus the Hewlett Packard 15201A and Teledyne C-61339. The 12-month unconditional warranty is the longest promise a cell vendor can make, and Sensoronics prints it on the product page.
Features and Benefits
Cell Design
- Galvanic Fuel Cell: Electrochemical cell that produces a current output in proportion to oxygen partial pressure
- Direct Replacement Fit: Drops into the sensor housing of Dräger anesthesia machines, ventilators and analyzers that take the 6850645 cell
- Calibration at 100 Percent Oxygen: The manufacturer directs calibration at 100% O2 rather than room air for this cell class
Compatibility
- Dräger 6850645 Replacement: Built as the compatible replacement for Dräger 6850645 and 6803290 oxygen sensors
- Host Machine Fit: Works in Dräger Narkomed, Babylog 8000, Evita and Fabius machines, Hewlett Packard 15201A and Teledyne C-61339
- Cross-Referenced Equivalents: Matches Analytical Industries PSR-11-915-2, City Technology MOX-16, Envitec OOM201, Maxtec MAX-11 and Teledyne R-23MED ordering numbers
Product Specifications
Sensor Details
- Sensor Type: Galvanic medical oxygen sensor (O2 cell)
- Replaces: Dräger 6850645 and 6803290
- Applications: Anesthesia machines, ventilators, incubators, oxygen analyzers and oxygen monitors
- Warranty: 12-month unconditional warranty
Browse the full Oximeter Accessories range, or shop everything from Sensoronics.
Why Biomed Teams Stock the SS-14A
An oxygen cell is a small part with an outsized job: every oxygen number the anesthesia machine shows starts here. The SS-14A matches the Dräger fit, carries the widest cross-reference list in its class, and ships with an unconditional year of coverage.
- Unconditional 12-Month Warranty – The warranty carries no conditions, so a cell that fades early is covered for a full year from placement.
- Direct Dräger Fit – The cell replaces the 6850645 outright, so the swap and the calibration follow the routine the team already runs.
- Wide Cross-Reference Cover – Equivalents span Analytical Industries, City Technology, Envitec, Maxtec and Teledyne numbers, so one stocked cell answers several legacy part calls.
- Fleet-Wide Coverage – Narkomed, Babylog, Evita and Fabius hosts share the cell, so one shelf item covers anesthesia and ICU machines.
Frequently Asked Questions
What does the SS-14A replace?
It replaces the Dräger 6850645 and 6803290 medical oxygen sensors and cross-references to Analytical Industries PSR-11-915-2, City Technology MOX-16, Envitec OOM201, Maxtec MAX-11 and Teledyne R-23MED.
Which machines use this cell?
Compatible hosts include the Dräger Narkomed 1A, 2, 2B, 3, 4 and 6000, Babylog 8000, Evita, Evita 2, Evita 4, Evita XL, Evita 2 Dura, Fabius and Fabius GS, plus the Hewlett Packard 15201A and Teledyne C-61339.
How does a galvanic oxygen cell work?
The electrochemical cell generates a current when exposed to oxygen, and the current is proportional to oxygen partial pressure, which the host machine converts into an oxygen reading.
How should the cell be calibrated?
The manufacturer directs calibration at 100% oxygen rather than room air for medical oxygen sensors of this class.
What warranty covers the cell?
The manufacturer warranty is a 12-month unconditional warranty.
Where is the cell used?
It serves anesthesia machines, ventilators, incubators, oxygen analyzers and oxygen monitors that take the 6850645 cell form.