Description
The Sensoronics SS-20A Medical Oxygen Sensor is a galvanic oxygen cell that replaces the Datex-Ohmeda 6050-0004-110 sensor in anesthesia machines and oxygen analyzers.
Oxygen readings anchor anesthesia decisions, and a cell at the end of its life drifts quietly, so planned replacement keeps the numbers honest.
- Galvanic Fuel Cell – The electrochemical cell generates a current in proportion to oxygen partial pressure, so the host machine reads oxygen directly from the cell output.
- Ohmeda 6050-0004-110 Replacement – Built as the compatible replacement for the Datex-Ohmeda 6050-0004-110 sensor, so the swap follows the original service routine.
- GE Anesthesia Fit – The cell serves the Excel 210, Modulus, Aestiva and Aisys lines, so one cell covers the GE anesthesia fleet.
- 12-Month Unconditional Warranty – The manufacturer backs the cell with a 12-month unconditional warranty, so a short-lived cell is covered.
The Galvanic Cell Behind Accurate Oxygen Readings
Medical oxygen sensors are consumables with a finite life: the galvanic cell reacts with oxygen, and output fades as the cell ages. The SS-20A is Sensoronics’ replacement cell for the Datex-Ohmeda 6050-0004-110, the sensor behind oxygen monitoring on GE anesthesia workstations. Biomed teams swap the cell on the machine’s service schedule and calibrate at 100% oxygen per the manufacturer guide.
The cell also cross-references to Analytical Industries PSR-11-915-4, C&S G0-100, Ceramatec CAG-10, City Technology MOX-7, Envitec OOM110, Integral Process 65008, Maxtec MAX-10, Mercury Medical 10-103-10, Nuova E-15/4, Pacifitech PT-20A, Sensidyne SV-20A, Teledyne R-30MED, Ventrex V-20A, Viamed R-30V and VTI 103105. Compatible hosts include the GE Datex-Ohmeda Excel 210, Modulus SE1700 and SE7900, Smart Vent, S-5, Aespire and Advance, Aestiva 3000 and Aisys. The 12-month unconditional warranty is printed on the manufacturer product page.
Features and Benefits
Cell Design
- Galvanic Fuel Cell: Electrochemical cell that produces a current output in proportion to oxygen partial pressure
- Direct Replacement Fit: Drops into the sensor housing of GE Datex-Ohmeda anesthesia machines that take the 6050-0004-110 cell
- Calibration at 100 Percent Oxygen: The manufacturer directs calibration at 100% O2 rather than room air for this cell class
Compatibility
- Datex-Ohmeda 6050-0004-110 Replacement: Built as the compatible replacement for the Datex-Ohmeda 6050-0004-110 oxygen sensor
- Host Machine Fit: Works in GE Datex-Ohmeda Excel 210, Modulus SE1700 and SE7900, Smart Vent, S-5, Aespire, Aestiva 3000 and Aisys machines
- Cross-Referenced Equivalents: Matches Analytical Industries PSR-11-915-4, City Technology MOX-7, Envitec OOM110, Maxtec MAX-10 and Teledyne R-30MED ordering numbers
Product Specifications
Sensor Details
- Sensor Type: Galvanic medical oxygen sensor (O2 cell)
- Replaces: Datex-Ohmeda 6050-0004-110
- Applications: Anesthesia machines, ventilators, incubators, oxygen analyzers and oxygen monitors
- Warranty: 12-month unconditional warranty
Browse the full Oximeter Accessories range, or shop everything from Sensoronics.
Why Biomed Teams Stock the SS-20A
An oxygen cell is a small part with an outsized job: every oxygen number the anesthesia machine shows starts here. The SS-20A matches the Ohmeda fit, carries a wide cross-reference list, and ships with an unconditional year of coverage.
- Unconditional 12-Month Warranty – The warranty carries no conditions, so a cell that fades early is covered for a full year from placement.
- Direct Ohmeda Fit – The cell replaces the 6050-0004-110 outright, so the swap and the calibration follow the routine the team already runs.
- Wide Cross-Reference Cover – Equivalents span Analytical Industries, City Technology, Envitec, Maxtec and Teledyne numbers, so one stocked cell answers several legacy part calls.
- Fleet-Wide Coverage – Excel, Modulus, Aestiva and Aisys hosts share the cell, so one shelf item covers the GE anesthesia fleet.
Frequently Asked Questions
What does the SS-20A replace?
It replaces the Datex-Ohmeda 6050-0004-110 medical oxygen sensor and cross-references to Analytical Industries PSR-11-915-4, City Technology MOX-7, Envitec OOM110, Maxtec MAX-10 and Teledyne R-30MED.
Which machines use this cell?
Compatible hosts include the GE Datex-Ohmeda Excel 210, Modulus SE1700 and SE7900, Smart Vent, S-5, Aespire and Advance, Aestiva 3000 and Aisys anesthesia machines.
How does a galvanic oxygen cell work?
The electrochemical cell generates a current when exposed to oxygen, and the current is proportional to oxygen partial pressure, which the host machine converts into an oxygen reading.
How should the cell be calibrated?
The manufacturer directs calibration at 100% oxygen rather than room air for medical oxygen sensors of this class.
What warranty covers the cell?
The manufacturer warranty is a 12-month unconditional warranty.
Where is the cell used?
It serves anesthesia machines, ventilators, incubators, oxygen analyzers and oxygen monitors that take the 6050-0004-110 cell form.