Description
The Welch Allyn Midmark IQecg Cable Kit is a patient cable kit for the Midmark IQecg, in the Mortara Burdick pattern that the IQecg system uses. It suits practices running the Midmark IQecg replacing a worn patient cable kit.
- For Midmark IQecg – the kit is made for the Midmark IQecg ECG system
- Mortara Burdick Pattern – the cable follows the Mortara Burdick design the IQecg is built on
- Complete Kit – the patient cable comes as a kit for a straight swap onto the system
The Patient Cable Kit for the Midmark IQecg
The Midmark IQecg is built on Mortara Burdick ECG technology, and its patient cable kit follows that pattern. This kit replaces the IQecg patient cable as a complete unit. Patient cables flex at the same points thousands of times, and intermittent conductors there print artifact that mimics cardiac findings. A complete kit swap restores the whole cable path at once instead of chasing which segment failed. Practices keep the IQecg tracing clean by treating its cable as the wear part it is.
Features and Benefits
Kit Design
- Patient Cable Kit: The kit supplies the IQecg patient cable as a complete replacement.
- Mortara Burdick Pattern: The cable follows the design the IQecg system uses.
Service Use
- Signal Path Renewal: It replaces cables with intermittent or damaged conductors.
- Straight Swap: The kit format suits a single replacement job.
Product Specifications
Product Details
- Product Type: Patient cable kit
- Compatibility: Midmark IQecg (Mortara Burdick pattern)
Packaging
- Package Contents: one IQecg patient cable kit
Reference
- Manufacturer SKU: 60-00184-01
Browse the full Professional Use range, or shop everything from Welch Allyn.
Why the IQecg Cable Is Replaced as a Kit
Intermittent cable faults are the hardest ECG problems to chase and the easiest to end with a full cable swap. This genuine kit restores the IQecg patient cable path in the Mortara Burdick pattern it was built with.
- Whole Path Renewal – the complete kit ends segment by segment fault chasing
- Pattern Correct – the cable matches the Mortara Burdick design of the IQecg
- Trace Quality – sound conductors keep resting traces free of cable artifact
Frequently Asked Questions
What is this cable kit used for?
It connects the Midmark IQecg to its patient lead connections for resting ECG recording. It replaces worn or intermittent patient cable kits.
Does the kit include electrodes?
No. This is the patient cable kit. Electrodes and other consumables are separate supply items.
How is this product sold?
Sold by the each: one IQecg patient cable kit, pricing is per each, as packed by the manufacturer, and the packaging section above shows the counts.
Why is it listed under Welch Allyn?
The IQecg ECG technology is Mortara Burdick, part of the Welch Allyn family of cardiology brands, and the cable kit follows that pattern.
Is this the genuine Welch Allyn product?
Yes, the cable kit on this listing is a genuine Welch Allyn product. Its manufacturer SKU is 60-00184-01, which is also the fastest way to reorder the identical item.
How do I know the cable is failing?
Artifact that changes when the cable is moved or flexed, with fresh electrodes and good skin prep, points at the cable.