Description
The Wellell Procare Bariatric G2 Alternating Pressure Mattress was designed from the start for bariatric patients, with wider surfaces, reinforced cells and a 990 lb capacity. Anyone who has tried to settle a large patient on a standard-width surface knows the compromise it forces on skin, dignity and staff safety, and this system ends that compromise. Automatic firmness and micro low air loss serve patients at high to very high risk in hospital and care facility bariatric programs.
- 990 lb Working Capacity – The surface supports up to 450 kg, covering bariatric patients that standard mattresses simply exclude.
- Wider, Tighter-Packed Cells – Larger and more densely packed air cells improve comfort and stability under larger bodies.
- Automatic Firmness Adjustment – The pump optimizes firmness to the patient’s weight, so setup stays accurate without manual calculation.
- Micro Low Air Loss – Ventilation wicks moisture from the skin and improves microclimate control across a larger contact area.
Reinforced Cells Sized for Bariatric Bodies
Bariatric pressure care fails when a standard surface is simply worked harder, so this system changes the structure instead. Rectangular air cells are packed more tightly across 42 and 48 in widths, with structurally reinforced cells in the torso section for sitting support. Additional cells beneath the controlled layer maintain firmness and prevent bottoming out, while dual compressors keep the large surface inflated and cycling. Alternating, continuous low pressure and alternating low pressure modes adapt therapy as the care plan changes. The result is a surface that treats bariatric patients as its design case, not as an overload exception.
Features and Benefits
Bariatric Pressure Care
- High-Capacity Support: A 990 lb maximum patient weight covers the full bariatric range on one surface.
- Reinforced Torso Cells: Structurally enhanced air cells in the torso section support sitting and repositioning without collapse.
- Anti-Bottoming Cell Layer: Additional air cells under the controlled cells maintain firmness to prevent bottoming out.
Workflow and Comfort
- Automatic Firmness Calibration: The pump auto-adjusts firmness to patient weight, simplifying care delivery for every admission.
- Dual Compressor System: Twin compressors inflate and maintain the wide surface quietly and continuously.
- Moisture-Managing Ventilation: Micro low air loss improves skin microclimate control for long bariatric stays.
Product Specifications
Mattress Specifications
- Mattress Type: Replacement
- Mattress Dimensions: 78.7 x 42 x 8 in or 78.7 x 48 x 8 in (200 x 107 or 122 x 20.3 cm)
- Mattress Weight: 28.7 lb (13 kg)
- Maximum Patient Weight: 990 lb (450 kg)
- Cover Material: Nylon/PU, vapor permeable
- Cell Material: Thermal polyurethane (TPU) laminated to medical-grade nylon
Pump and Therapy Specifications
- Pump Dimensions: 13.4 x 5.3 x 8 in (34 x 13.5 x 20.3 cm)
- Pump Weight: 8.4 lb (3.8 kg)
- Therapy Modes: Max Firm, Alternating, Continuous Low Pressure and Alternating Low Pressure
- Cycle Times: 10, 15, 20 or 25 minutes
Browse the full Bariatric Mattresses range, or shop everything from Wellell.
Why Bariatric Care Needs a Wider, Stronger Surface
Pressure injury risk climbs steeply with body mass, and the work of repositioning grows heavier at the same time. A purpose-built bariatric surface answers both sides of that problem, with capacity and width that protect skin and a structure that protects the staff moving the patient. Facilities stop improvising with standard equipment that was never rated for the load.
- Rated, Not Improvised – A published 990 lb capacity replaces guesswork about standard surfaces.
- Width That Fits – 42 and 48 in sizes give larger patients full support without edge spillover.
- Safer Handling – Stable, reinforced cells make repositioning more controlled for caregivers.
- Full Therapy Range – Four modes, including alternating low pressure, match therapy to fragile bariatric skin.
Manuals and Troubleshooting Guides
Wellell Procare Bariatric G2 Alternating Pressure Mattress – Product Brochure
Frequently Asked Questions
What widths does this mattress come in?
It comes in 42 in and 48 in widths, both at 78.7 in long and 8 in deep. Choose the width that matches the bariatric bed frame and the patient’s body.
How much weight can it support?
The maximum patient weight is 990 lb, or 450 kg. That rating applies across both width options in this configuration.
How does the automatic firmness work?
The pump senses the patient’s weight and calibrates mattress firmness automatically. Caregivers do not need to calculate settings for each new admission.
What therapy modes are included?
Modes include Max Firm, Alternating, Continuous Low Pressure and Alternating Low Pressure. The range lets the care team shift from procedures to gentle long-term therapy on one surface.
Is this a replacement mattress or an overlay?
It is a full replacement mattress that takes the place of the standard bed mattress. The 8 in depth provides the complete support surface for the bariatric bed.