Description
Nonin 8000J PureLight Reusable Adult Flex SpO2 Sensor with FlexiWrap in 1 and 3 Meter Cable Lengths
The Nonin 8000J Flex Sensor wraps onto the finger with a FlexiWrap for a secure fit on adults over 20 kilograms. The wrap format holds alignment through movement, making it a favorite for continuous monitoring and longer studies.
- Flex sensor secured with a disposable FlexiWrap for stable placement
- For adults over 20 kg, applied to index, middle or ring fingers
- Declared accuracy within 2 digits from 70 to 100 percent
- 1 and 3 meter cable options
8000J Adult Flex Sensor for Secure Wrapped Placement
Some patients and protocols defeat clip sensors, particularly during continuous monitoring where a clip can shift or be knocked loose. The flex design answers with a low profile sensor element that the FlexiWrap holds in alignment on the finger. Preferred application sites are the index, middle or ring fingers of patients over 20 kilograms. PureLight LED technology maintains the signal quality that PureSAT processing turns into accurate saturation values. The format is a staple for sleep and monitoring applications where the sensor must stay put for hours. Replacement FlexiWraps are stocked separately, so the reusable sensor element serves across many patients.
Features and Benefits
Wrapped Security
- FlexiWrap Attachment – the adhesive wrap holds the sensor in alignment through movement.
- Low Profile Element – the flex form sits flatter than a clip for long wear periods.
- Adult Finger Sites – index, middle or ring fingers on patients over 20 kg.
Performance
- PureLight Output – clean spectrum LEDs support accuracy at critical levels.
- Within 2 Digits – declared accuracy across the 70 to 100 percent range.
- Two Cable Lengths – 1 and 3 meter versions for bedside and cart setups.
Product Specifications
Performance
- SpO2 Accuracy: 70 to 100% within 2 digits (Arms)
- Patient Range: Adults over 20 kg (44 lb)
- Application Site: Index, middle or ring finger, wrap secured
- Sensor Technology: PureLight LED flex sensor, reusable
Configuration
- Cable Lengths: 1 m and 3 m options
- Attachment: FlexiWrap sensor wraps, sold separately
- Compatibility: Nonin pulse oximeters per the manufacturer Sensor Compatibility Guide
- Package: Sold individually
See all Oximeter Accessories for the full range, or Shop more Nonin Products for the complete line.
Why Monitoring Programs Choose the 8000J Flex Format
A sensor that migrates during a study produces data nobody can defend. The wrapped flex format trades a few seconds of application time for hours of positional stability.
- Stable Long Studies – the wrap keeps emitter and detector aligned through the night.
- Comfort Over Hours – the low profile element avoids clip pressure on the digit.
- Consumable Economy – only the wrap is disposable, while the sensor element is reused.
- Proven Accuracy – the same 2 digit PureLight declaration as the clip line.
Manuals and Troubleshooting Guides
Frequently Asked Questions (FAQs)
How is the 8000J attached?
The flex sensor is placed on the finger and secured with a FlexiWrap adhesive wrap. Wraps are disposable and are replaced between patients.
Which patients and fingers does it fit?
The manufacturer specifies adults over 20 kg, applied to the index, middle or ring fingers. Infant and neonatal flex sensors are listed separately.
What cable lengths are offered?
Choose 1 meter or 3 meter cable versions from the option list. Both use the same flex sensor element.
How accurate is the flex sensor?
The manufacturer declares accuracy within 2 digits over the 70 to 100 percent range. The value derives from induced hypoxia studies with PureSAT technology.
Are FlexiWraps included?
The sensor is sold on its own, and FlexiWrap packs for adult, infant and neonatal flex sensors are listed separately in this catalog. That keeps the reusable element in service while the wraps are treated as the consumable.