Nonin 8000J-WO2 PureLight Reusable Flex SpO2 Sensor for WristOx2 3150, 16-Pin, Includes 25 FlexiWraps
The Nonin 8000J-WO2 Flex Sensor is the Flex PureLight sensor made for the WristOx2 3150 wrist-worn oximeter. Its 16-pin connector and short 30 cm cable are proportioned for wrist-worn recording, and this flex configuration ships with 25 FlexiWraps so the first studies can start immediately.
- Made for WristOx2 3150 USB and BLE recorders
- 16-pin WO2 connector with a 30 cm (12 in) cable
- PureLight LED technology for PureSAT processing
- 8000J-WO2 Flex format in the WO2 sensor family
8000J-WO2 Flex Sensor for WristOx2 3150 Recording
Flex sensors earn their place in recording programs when clips will not stay on overnight. The low profile element wraps onto the finger and the FlexiWrap holds it in alignment while the patient sleeps and moves. This WO2 configuration also includes 25 FlexiWraps in the box, so a program can start recording before its first wrap reorder. The 16-pin connector and 30 cm cable match the WristOx2 recorder's wrist to finger geometry. Patients who fidget with clips often forget a wrapped flex sensor entirely, which protects study completion rates. PureLight output keeps the wrapped recordings on the same accuracy footing as the clip studies.
Features and Benefits
WristOx2 Fit
- 16-Pin WO2 Connector – the 16-pin standard for the 3150, here on the 8000J-WO2 flex.
- 30 cm Cable – short cable geometry matched to wrist to finger routing on the 8000J-WO2.
- PureLight LEDs – clean spectrum output for the PureSAT engine reading the 8000J-WO2.
Program Use
- Reusable Across Studies – the 8000J-WO2 serves patient after patient with standard cleaning.
- Five Style Family – the 8000J-WO2 shares its connector with the clip, flex and soft sizes.
- Study Ready – the 8000J-WO2 is built for overnight and ambulatory recording protocols.
Product Specifications
Performance
- Sensor Technology: PureLight LED, reusable
- Style: 8000J-WO2 Flex
- Intended Devices: WristOx2 Model 3150 USB and 3150 BLE
- Connector: 16-pin WO2
Configuration
- Cable Length: 30 cm (12 in)
- Compatibility: WristOx2 3150 per the manufacturer Sensor Compatibility Guide
- Package: Sold individually
- Latex: Not made with natural rubber latex
- Included: 25 FlexiWraps
See all Oximeter Accessories for the full range, or Shop more Nonin Products for the complete line.
Why Programs Stock the 8000J-WO2 WO2 Sensor
Clips fail some patients every night, and a failed night is a rescheduled study. A wrapped flex option on the shelf rescues those patients instead of sending them home unrecorded.
- Rescue for Clip Failures – the wrap secured format stays on patients who dislodge clips in their sleep.
- Wraps in the Box – 25 FlexiWraps are included, so the first studies need no separate wrap order.
- Low Profile Comfort – the flex element sits flatter than a clip for overnight wear.
- PureLight Consistency – wrapped studies carry the same signal standard as clip studies.
Manuals and Troubleshooting Guides
Frequently Asked Questions (FAQs)
Which recorders does this sensor fit?
It connects to the WristOx2 Model 3150, USB and Bluetooth versions, through its 16-pin WO2 connector. That connector is specific to the wrist recorder family.
Are FlexiWraps included?
Yes. This configuration includes 25 FlexiWraps for securing the sensor during studies, and replacement wrap packs are listed separately.
What cable length does it have?
The cable is 30 cm, about 12 inches, matched to wrist to finger routing. It is deliberately short for a wrist worn system.
When is flex preferred over the clip for recording?
Flex suits patients who pull clips off, move heavily in sleep or need the sensor to stay aligned for many hours. The wrap holds position the way a clip cannot.
Is the sensor reusable?
Yes. The flex element is reusable across patients, while the FlexiWraps are single patient disposables.