null
Nonin

Nonin 8001J PureLight Reusable Neonatal Flex SpO2 Sensor with FlexiWrap Attachment, 1 Meter Cable

(No reviews yet) Write a Review
SKU:
0739-000
Shipping:
Calculated at Checkout
  • Nonin 8001J PureLight Reusable Neonatal Flex SpO2 Sensor with FlexiWrap Attachment, 1 Meter Cable
  • Nonin 8001J PureLight Reusable Neonatal Flex SpO2 Sensor with FlexiWrap Attachment, 1 Meter Cable
$187.99
Fast Delivery
Fast Delivery
Most ship in 1–2 days
Shipping
$50+ Ship Free
Flat $6.95
30-Day Returns
30-Day Returns
No questions asked
Secure Payment
Secure Payment
100% safe checkout

Description

Nonin 8001J PureLight Reusable Neonatal Flex SpO2 Sensor with FlexiWrap Attachment, 1 Meter Cable

The Nonin 8001J Neonatal Flex Sensor is the smallest member of the PureLight flex family, made for neonatal patients. Its wrap secured element fits neonatal fingers and feet where even infant sensors are too large.

  • Neonatal sized flex element for the smallest patients
  • FlexiWrap attachment for gentle, stable placement
  • PureLight LED technology for accuracy at critical levels
  • Declared accuracy within 2 digits from 70 to 100 percent

8001J Neonatal Flex Sensor for NICU and Nursery Monitoring

Neonatal monitoring leaves no room for sensor improvisation, because neonatal digits and feet accept only correctly sized hardware. This sensor is the neonatal entry in the flex family, with an element proportioned for neonatal application sites. The FlexiWrap system secures the element without clip pressure, an important comfort and skin consideration for neonatal patients. PureLight LED output feeds the PureSAT processing in connected monitors, keeping low saturation readings dependable. The reusable element works with disposable neonatal FlexiWraps that are changed between patients. Declared accuracy matches the rest of the flex family at within 2 digits from 70 to 100 percent.

Features and Benefits

Neonatal Design

  • Smallest Flex Element – proportioned for neonatal fingers and feet.
  • No Clip Pressure – wrap attachment avoids pinching delicate skin.
  • PureLight LEDs – engineered light output for critical level accuracy.

Use Pattern

  • Reusable Sensor – the element is reused while wraps are single patient.
  • Within 2 Digits – declared accuracy across the clinical saturation range.
  • 1 Meter Cable – suited to incubator and warmer placements.

Product Specifications

Performance

  • SpO2 Accuracy: 70 to 100% within 2 digits (Arms)
  • Patient Group: Neonates
  • Application Site: Finger or foot, wrap secured
  • Sensor Technology: PureLight LED flex sensor, reusable

Configuration

  • Cable Length: 1 m
  • Attachment: 8001JFW neonatal FlexiWrap wraps, sold separately
  • Compatibility: Nonin pulse oximeters per the manufacturer Sensor Compatibility Guide
  • Package: Sold individually

See all Oximeter Accessories for the full range, or Shop more Nonin Products for the complete line.

Why Nurseries Choose the 8001J Neonatal Flex Sensor

Neonatal teams standardize on hardware that fits correctly the first time. A dedicated neonatal element removes the temptation to adapt larger sensors to the smallest patients.

  • Correct Neonatal Fit – the element is proportioned for neonatal sites, not adapted from infant stock.
  • Skin Friendly Attachment – wrap securing avoids clip pressure on fragile skin.
  • Dependable Low Readings – PureLight output supports accuracy where neonatal decisions are made.
  • Hygienic Turnover – disposable neonatal wraps are replaced between patients.

Manuals and Troubleshooting Guides

Frequently Asked Questions (FAQs)

Which patients is the 8001J designed for?

It is the neonatal member of the flex sensor family, sized for neonatal fingers and feet. The infant 8008J is the next size up and is listed separately.

How is it secured?

The element is held by an 8001JFW neonatal FlexiWrap adhesive wrap. Wraps are disposable and available separately.

What accuracy is declared?

Within 2 digits across the 70 to 100 percent saturation range. The declaration follows the PureLight and PureSAT system testing.

What cable does it use?

A 1 meter cable, suited to incubator and radiant warmer monitor placement. That is the standard cable length for the neonatal flex model.

Which monitors accept it?

Nonin monitors compatible with PureLight flex sensors, per the manufacturer Sensor Compatibility Guide. The guide lists supported models across the tabletop and handheld ranges.

View AllClose

Warranty Information

This product may be covered under the manufacturer's original warranty. Please refer to the manufacturer's documentation or contact us for assistance.
View AllClose

0 Reviews

View AllClose

Explore our wide range of medical products, enjoy hassle-free shopping, and take advantage of our exclusive offers. Free shipping on orders over $50! Need assistance? Contact our friendly customer support team at (800) 494-5750. Happy shopping!