Description
Nonin 8008J PureLight Reusable Infant Flex SpO2 Sensor with FlexiWrap Attachment, 1 Meter Cable
The Nonin 8008J Infant Flex Sensor applies the flex and wrap format to infant patients. Its small sensor element and FlexiWrap attachment suit the tiny digits and feet of infants who defeat standard clips.
- Infant sized flex sensor element for small digits and feet
- FlexiWrap attachment holds alignment on active infants
- PureLight LED technology for accuracy at critical levels
- Declared accuracy within 2 digits from 70 to 100 percent
8008J Infant Flex Sensor for the Smallest Monitored Patients
Infant oximetry demands sensor geometry that matches infant anatomy, not a shrunken guess. This flex sensor was designed as the infant member of the 8000J family, with an element sized for infant fingers and toes. The FlexiWrap attachment secures the sensor gently, keeping emitter and detector aligned while the infant moves. PureLight LED output supports the PureSAT processing in Nonin monitors, maintaining declared accuracy within 2 digits across the clinical range. The reusable element pairs with disposable infant FlexiWraps, which are replaced between patients for hygiene. It connects across the Nonin monitor range that accepts PureLight flex sensors.
Features and Benefits
Infant Design
- Infant Sized Element – geometry matched to infant digits and feet.
- Wrap Secured Fit – the FlexiWrap holds alignment through normal infant movement.
- PureLight LEDs – clean spectrum light for dependable low level readings.
Use Pattern
- Reusable Sensor – the element serves across patients while wraps are disposable.
- Within 2 Digits – declared accuracy from 70 to 100 percent saturation.
- 1 Meter Cable – length suited to cot and incubator monitor placement.
Product Specifications
Performance
- SpO2 Accuracy: 70 to 100% within 2 digits (Arms)
- Patient Group: Infants
- Application Site: Finger or toe, wrap secured
- Sensor Technology: PureLight LED flex sensor, reusable
Configuration
- Cable Length: 1 m
- Attachment: 8008JFW infant FlexiWrap wraps, sold separately
- Compatibility: Nonin pulse oximeters per the manufacturer Sensor Compatibility Guide
- Package: Sold individually
See all Oximeter Accessories for the full range, or Shop more Nonin Products for the complete line.
Why Infant Units Stock the 8008J Flex Sensor
Infant readings are hard enough without fighting sensor fit. A purpose sized flex element with a wrap that stays put gives staff one less variable during assessments.
- Fit That Holds – wrap attachment resists the kicking and grasping that dislodge clips.
- Gentle on Small Digits – the flex format distributes contact instead of pinching.
- Hygienic Turnover – disposable wraps handle the infection control step between patients.
- Family Consistency – application mirrors the adult and neonatal flex sensors staff already know.
Manuals and Troubleshooting Guides
Frequently Asked Questions (FAQs)
Which patients is the 8008J for?
It is the infant member of the Nonin flex sensor family, sized for infant fingers and toes. The neonatal 8001J and adult 8000J are listed separately.
How does it attach?
The sensor is placed and secured with an 8008JFW infant FlexiWrap. Wraps are disposable and sold separately in this catalog.
How accurate is it?
Declared accuracy is within 2 digits across the 70 to 100 percent saturation range. Performance derives from the PureLight and PureSAT pairing.
What cable length does it have?
The infant flex sensor comes with a 1 meter cable. That length suits incubator and cot side monitor setups.
Which monitors does it connect to?
Nonin monitors that accept PureLight flex sensors, per the manufacturer Sensor Compatibility Guide. Checking the guide against your monitor model is the reliable way to confirm a pairing.