Description
Nonin 8000R PureLight Reusable Forehead Reflectance SpO2 Sensor with 8000H Forehead Sensor Holder Kit
The Nonin 8000R Forehead Reflectance Sensor reads saturation from the middle of the forehead when digit sites are not preferred. This configuration includes the 8000H forehead holder kit, so the sensor arrives ready to apply and keep in place.
- Forehead reflectance site for stress testing and continuous monitoring
- Includes the 8000H forehead sensor holder kit
- Declared accuracy within 2 digits from 70 to 100 percent
- Central site that can respond faster than peripheral digits
8000R Forehead Reflectance Sensor for Alternative Site Monitoring
Forehead reflectance oximetry serves the situations where fingers underperform, including stress testing and continuous monitoring during procedures. Placed in the middle of the forehead, the sensor reads from a central site with strong perfusion characteristics. The manufacturer highlights this placement for stress testing and for continuous monitoring where digits are not the preferred application site. PureLight technology keeps the reflectance signal clean, with declared accuracy within 2 digits across the saturation range. The included 8000H holder kit secures the sensor at the site, replacing improvised tape jobs. The sensor is reusable and connects across the Nonin monitor range.
Features and Benefits
Forehead Site
- Reflectance Sensing – reads from the forehead surface rather than through a digit.
- Central Perfusion – the forehead site suits stress testing and procedural monitoring.
- Holder Kit Included – the 8000H holder secures placement without improvised fixings.
Performance
- Within 2 Digits – declared accuracy from 70 to 100 percent saturation.
- PureLight LEDs – clean spectrum output for PureSAT processing.
- Reusable Format – the sensor serves across patients with standard cleaning.
Product Specifications
Performance
- SpO2 Accuracy: 70 to 100% within 2 digits (Arms)
- Application Site: Middle of forehead, reflectance
- Sensor Technology: PureLight reflectance sensor, reusable
- Intended Uses: Stress testing and continuous monitoring where digits are not preferred
Configuration
- Included: 8000H forehead sensor holder kit
- Compatibility: Nonin pulse oximeters per the manufacturer Sensor Compatibility Guide
- Package: Sensor with holder kit
- Latex: Not made with natural rubber latex
See all Oximeter Accessories for the full range, or Shop more Nonin Products for the complete line.
Why Procedural Areas Choose the 8000R Forehead Sensor
Hands get in the way during procedures, and peripheral sites lag during stress testing. A forehead sensor with a proper holder gives those settings a declared, repeatable alternative site.
- Hands Stay Free – the forehead site leaves digits available for the procedure.
- Holder Included – the 8000H kit secures the sensor as the manufacturer intends.
- Central Site Response – forehead perfusion supports monitoring through changing conditions.
- Standard Accuracy – the 2 digit PureLight declaration matches the finger sensor line.
Manuals and Troubleshooting Guides
Frequently Asked Questions (FAQs)
Where is the 8000R placed?
It is placed in the middle of the forehead and held by the included 8000H forehead sensor holder kit. The operator manual illustrates exact placement.
When is a forehead sensor preferred?
The manufacturer cites stress testing and continuous monitoring where digits are not the preferred application site. Procedural settings with occupied or poorly perfused hands are common examples.
What comes with this configuration?
The package includes the 8000R sensor and the 8000H forehead sensor holder kit. The holder kit secures the sensor at the forehead site for each application.
How accurate is the forehead sensor?
The declared figure is within 2 digits from 70 to 100 percent. The declaration follows PureLight system testing.
Which monitors does it fit?
Nonin oximeters accepting PureLight sensors, per the manufacturer Sensor Compatibility Guide. The guide is the authority for model level compatibility.